HP UX Internet and Networking Software manual 242

Models: UX Internet and Networking Software

1 651
Download 651 pages 11.83 Kb
Page 242
Image 242

Administration Commands

define_tr_port, define_ethernet_port, define_fddi_port

Name of the associated DLC. This name is a character string using any locally displayable characters. The specified DLC must have already been defined.

port_number

The number of the port.

max_rcv_btu_size

Maximum BTU size that can be received. This value includes the length of the TH and RH (total 9 bytes) as well as the RU. Specify a value in the range 26565535.

tot_link_act_lim

Total link activation limit (the maximum number of links that can be active at any time using this port).

inb_link_act_lim

Inbound link activation limit (the number of links reserved for inbound activation). The sum of inb_link_act_lim and out_link_act_lim must not exceed tot_link_act_lim; the difference between inb_link_act_lim and tot_link_act_lim defines the maximum number of links that can be activated outbound at any time.

out_link_act_lim

 

 

 

 

Outbound link activation

limit (the number of

links reserved for outbound

activation).

The sum

of inb_link_act_lim and

out_link_act_lim must

not exceed tot_link_act_lim;

the difference

between

out_link_act_lim and tot_link_act_lim defines the maximum number of links that can be activated inbound at any time.

ls_role

Link station role. Set this to LS_NEG.

implicit_dspu_services

Specifies the services that the local node will provide to the downstream PU across implicit links activated on this port. Possible values are:

DLUR

Local node will provide DLUR services for the downstream PU (using the default DLUS configured through the define_dlur_defaults command).

PU_CONCENTRATION

Local node will provide PU concentration for the downstream PU. It will also put in place definitions as specified by the DSPU template specified for the parameter implicit_dspu_template.

NONE

Local node will provide no services for this downstream PU.

implicit_dspu_template

Specifies the DSPU template, defined on the define_dspu_template command. This template is used for definitions if the local node is to provide PU concentration for an implicit link activated on this port. If the template specified does not exist or is already at its instance limit when the link is activated, activation will fail. This template name is an 8-byte string in a locally displayable character set.

If the implicit_dspu_services parameter is not set to PU_CONCENTRATION, the implicit_dspu_template parameter is reserved.

implicit_ls_limit

Specifies the maximum number of implicit link stations which can be active on this port simultaneously, including dynamic links and links activated for Discovery. Specify a value in the range 165,534or specify 0 (zero) to indicate no limit. A value of NO_IMPLICIT_LINKS indicates that no implicit links are allowed.

242

Page 242
Image 242
HP UX Internet and Networking Software manual 242