Polycom 1500/1800/2000/4000 manual

Models: 1500/1800/2000/4000

1 1101
Download 1101 pages 34.66 Kb
Page 1003
Image 1003

Appendix G - Configuring Direct Connections to the Collaboration Server

6 Enter the IP address, Subnet mask and Default gateway for the workstation.

The workstation’s IP address should be in the same network neighborhood as the Collaboration Server’s Control Unit IP address.

Example: IP address – in the network neighborhood of 192.168.1.nn

Note: Reserved IP Addresses

None of the reserved IP addresses listed in Reserved IP Addresses list below should be used for the IP Address.

The Subnet mask and Default gateway addresses should be the same as those for the Collaboration Server’s Management Network.

The addresses needed for connection to either the Collaboration Server’s Default Management Network or Alternate Management Network are listed in the table below.

For more information about connecting to the Alternate Management Network, see Appendix G - Configuring Direct Connections to the Collaboration Server.

Reserved IP Addresses

 

IP Address

 

 

 

 

Network Entity

Management Network (Factory Default)

Alternate Network

 

 

 

Control Unit IP Address

192.168.1.254

169.254.192.10

 

 

 

Control Unit Subnet Mask

255.255.255.0

255.255.240.0

 

 

 

Default Router IP Address

192.168.1.1

169.254.192.1

 

 

 

Shelf Management IP Address

192.168.1.252

169.254.192.16

 

 

 

Shelf Management Subnet Mask

255.255.255.0

255.255.240.0

 

 

 

Shelf Management Default Gateway

192.168.1.1

169.254.192.1

 

 

 