Defining Cascading Conferences

MIH Cascading – Video Session Mode and Line Rate

Topology

MCU Type

Video Session Mode

Line Rate

Endpoint

 

 

 

 

 

Level 1

MGC

VSW - HD

1.5Mb/s

HDX

 

 

 

 

 

Level 2

RealPresence

VSW - HD

 

 

 

Collaboration Server

 

 

 

 

 

 

 

 

To establish the links between two RealPresence Collaboration Servers requires the following procedures be performed:

Establish the Master-Slave relationships between the cascaded conferences by defining the dialing direction.

Create the Master and Slave conferences, defining the appropriate line rate.

Create a cascade-enabled Dial-out Participant link in the Master conference

Create a cascade-enabled Dial-in Participant link in the Slave conference.

Creating a Cascade Enabled Dial-out/Dial-in Participant Link

The connection between two cascaded conferences is established by a cascade enabled dial-out and dial-in participants, acting as a cascades link.

The dialing direction determines whether the dial-out participant is defined in the conference running on the Master MCU or the Slave MCU. For example, if the dialing direction is from the Master conference on level 1 to the Slave conference on level 2, the dial-out participant is defined in the Master conference on level 1 and a dial-in participant is defined in the Slave conference running on the MCU on level 2.

If the cascade-enabled dial-out participant always connects to the same destination conference on the other (second) MCU, the participant properties can be saved in the Address Book of the MCU for future repeated use of the cascaded link.

To define the dial-out cascade participant link:

1In the Conferences pane, select the conference.

Polycom®, Inc.

241

Page 272
Image 272
Polycom 1500/1800/2000/4000 manual To define the dial-out cascade participant link, Conferences pane, select the conference