Collaboration Server Hardware Monitoring

The status and properties of the Collaboration Server hardware components can be viewed and monitored in the Hardware Monitor list pane.

Viewing the Status of the Hardware Components

The Hardware Monitor’s status column displays the present status of the hardware components. In addition to the status, temperature and voltage indications are provided for each component.

For RMX 1500/2000/4000 systems, the MCU’s Shelf Management Server is what users are connecting to when accessing the Hardware Monitor pane. This pane can be accessed in either two ways: through the RMX Web Client or the Shelf Management Server. Connection via the Shelf Management Server enables users to access the Hardware Monitor even when the connection through the Collaboration Server Web Client is unavailable. The ability to connect directly via the Shelf Management Server enables users to: enter the Hardware Monitor and view the problematic hardware components, reset and restart the MCU and run diagnostics. Running diagnostics and restarting the MCU can only be done via direct connection to the Shelf Management Server.

When accessing the Shelf Management server, the content displayed will be available in English only.

Shelf Management is not supported on the RMX 1800.