Polycom 1500/1800/2000/4000 manual Active Alarms Alarm Code Alarm Description

Models: 1500/1800/2000/4000

1 1101
Download 1101 pages 34.66 Kb
Page 942
Image 942

Appendix B - Active Alarms

Active Alarms

Alarm Code

Alarm Description

 

 

SIP TLS: Registration server not responding

This alarm is displayed when the Collaboration Server does not receive a response from the OCS to the registration request in the expected time frame. Possible causes are:

The Collaboration Server FQDN name is not defined in the OCS pool, or is defined incorrectly.

The time frame for the expected response was too short and it will be

 

updated with the next data refresh. The alarm may be cleared

 

automatically the next time the data is refreshed.

 

The Collaboration Server FQDN name is not defined in the DNS

 

server. Ping the DNS using the Collaboration Server FQDN name to

 

ensure that the Collaboration Server is correctly registered to the DNS.

 

 

SIP TLS: Registration transport error

This alarm indicates that the communication with the SIP server cannot

 

be established. Possible causes are:

 

Incorrect IP address of the SIP server

 

The SIP server listening port is other than the one defined in the

 

system

 

The OCS services are stopped

 

 

Software upgrade in component

 

 

 

SSH is enabled

 

 

 

SWITCH not responding

Check the Switch card.

 

 

System Cards MPM Plus mode are not

 

supported in Event mode

 

 

 

System configuration changed. Please

 

reset the MCU

 

 

 

System Configuration modified

System configuration flags were modified. Reset the MCU.

 

 

System resources of Audio ports

 

usage has exceeded Port Gauge

 

threshold

 

 

 

System resources of Video ports

 

usage has exceeded Port Gauge

 

threshold

 

 

 

System resources usage has

 

exceeded Port Gauge threshold

 

 

 

Temperature Level - Critical

Temperature has reached a critical level.

 

 

Temperature Level - Major

Temperature has reached a problematic level and requires attention.

 

 

The Log file system is disabled

 

because of high system CPU usage

 

 

 

The MCCF channel is not connected

 

 

 

The software contains patch(es)

The software contains patch(es).

Polycom®, Inc.

911

Page 942