Entry Queues, Ad Hoc Conferences and SIP Factories

3Define the following parameters:

Entry Queue Definitions Parameters

Option

Description

 

 

Display Name

The Display Name is the conferencing entity name in native language character

 

sets to be displayed in the Collaboration Server Web Client.

 

In conferences, Meeting Rooms, Entry Queues and SIP factories the system

 

automatically generates an ASCII name for the Display Name field that can be

 

modified using Unicode encoding.

 

English text uses ASCII encoding and can contain the most characters

 

(length varies according to the field).

 

European and Latin text length is approximately half the length of the

 

maximum.

 

Asian text length is approximately one third of the length of the maximum.

 

The maximum length of text fields also varies according to the mixture of

 

character sets (Unicode and ASCII).

 

Maximum field length in ASCII is 80 characters. If the same name is already

 

used by another conference, Meeting Room or Entry Queue, the Collaboration

 

Server displays an error message requesting you to enter a different name.

 

 

Routing Name

Enter a name using ASCII text only. If no Routing Name is entered, the system

 

automatically assigns a new name as follows:

 

If an all ASCII text is entered in Display Name, it is used also as the Routing

 

Name.

 

If any combination of Unicode and ASCII text (or full Unicode text) is entered

 

in Display Name, the ID (such as Conference ID) is used as the Routing

 

Name.

 

 

Profile

Select the Profile to be used by the Entry Queue.

 

The default Profile is selected by default. This Profile determines the Bit Rate

 

and the video properties with which participants connect to the Entry Queue and

 

destination conference.

 

To connect to a Video Switching conference via Entry Queue, the Profile

 

assigned to the Entry Queue must be set to Video Switching. It is recommended

 

to use the same profile for both the destination conference and Entry Queue.

 

In Ad Hoc conferencing, it is used to define the new conference properties.

 

 

ID

Enter a unique number identifying this conferencing entity for dial in. Default

 

string length is 4 digits.

 

If you do not manually assign the ID, the MCU assigns one after the completion

 

of the definition. The ID String Length is defined by the flag

 

NUMERIC_CONF_ID_LEN in the System Configuration.

 

 