Appendix C - CDR Fields, Unformatted File

 

 

 

 

Event Fields for Event 5001 - CONFERENCE START CONTINUE 4

 

 

 

 

Field

Description

 

 

 

 

 

 

Info1

The contents of the conference information fields.

 

Info2

These fields enable users to enter general information for the conference, such as the

 

Info3

company name, and the contact person’s name and telephone number.

 

 

The maximum length of each field is 80 characters.

 

 

 

 

 

Billing Info

The billing code.

 

 

 

 

Event Fields for Event 6001 - CONFERENCE START CONTINUE 5

 

 

 

 

 

Field

Description

 

 

 

 

 

 

Encryption

Indicates the conference encryption setting, as follows:

 

 

0 - The conference is not encrypted.

 

 

1 - The conference is encrypted.

 

 

 

Event Fields for Event 11001 - CONFERENCE START CONTINUE 10

 

 

 

 

 

Field

Description

 

 

 

 

 

 

Display Name

The Display Name of the conference.

 

 

 

 

Event Fields for Event 2 - CONFERENCE END

 

 

 

 

 

Field

Description

 

 

 

 

 

Conference End Cause

Indicates the reason for the termination of the conference, as follows:

1 - The conference is an ongoing conference or the conference was terminated by an MCU reset.

2 - The conference was terminated by a user.

3 - The conference ended at the scheduled end time.

4 - The conference ended automatically because no participants joined the conference for a predefined time period, or all the participants disconnected from the conference and the conference was empty for a predefined time period.

5 - The conference never started.

6 - The conference could not start due to a problem.

8 - An unknown error occurred.

9 - The conference was terminated by a participant using DTMF codes.

Polycom®, Inc.

924

Page 955
Image 955
Polycom 1500/1800/2000/4000 Event Fields for Event 6001 Conference Start Continue, Event Fields for Event 2 Conference END