Configuration Requirements

LAN Redundancy is disabled by default and is enabled by changing the LAN_REDUNDANCY system flag to YES and connecting the appropriate LAN cables to the LAN ports on the Collaboration Server as follows:

RealPresence Collaboration Server (RMX) 1500

»Connect the additional LAN cable to LAN 1 port on the RTM IP.

RealPresence Collaboration Server 1800

»Connect the additional LAN cable to LAN 2 port on the rear panel of the Collaboration Server 1800.

RealPresence Collaboration Server (RMX) 2000

On a RealPresence Collaboration Server (RMX) 2000, one RTM LAN card is required.

For more information see the RealPresence Collaboration Server (RMX) 2000 Hardware Guide, Installing or Replacing the RTM LAN.

Connect the additional LAN cable to LAN 1 port on the RTM LAN.

In the Setup> System Configuration > System Flags dialog box, add the flag RMX2000_RTM_LAN and set it to YES to activate the installed RTM LAN card.

On the RealPresence Collaboration Server (RMX) 2000, LAN Redundancy can be enabled simultaneously with Multiple Networks. To enable the Multiple Networks option, set the MULTIPLE_SERVICES flag to YES.

A system reset is required when adding the RMX2000_RTM_LAN flag.

RealPresence Collaboration Server (RMX) 4000

Connect the additional LAN cable to LAN 1 port on the RTM LAN.

On the RealPresence Collaboration Server (RMX) 4000, LAN Redundancy can be enabled simultaneously with Multiple Networks. To enable the Multiple Networks option, set the MULTIPLE_SERVICES flag to YES.

If required, reset the Collaboration Server.

On all systems:

LAN Redundancy can be disabled by setting the LAN_REDUNDANCY System Flag to NO.

If the LAN_REDUNDANCY System Flag value set to NO, the LAN 2 port must be connected to the IP network.

On the RMX 1500/2000/4000, full media redundancy is supported if only one IP Network Service is defined per media card.

Hardware Monitor Indications

When LAN Redundancy is enabled on the Collaboration Server, LAN 2 port is Active. With LAN redundancy, when LAN LEDs are lit they indicate that a physical connection of the cables is present but