System Configuration Flags

 

 

 

 

Manually Added, Modified, Deleted System Flags

 

 

 

 

Flag

Description

 

 

 

 

 

 

CASCADE_LINK_PLAY_TONE_ON

When set to YES, the RealPresence Collaboration Server plays a tone

 

_CONNECTION

when a cascading link between conferences is established. The tone is

 

 

played in both conferences.

 

 

This tone is not played when the cascading link disconnects from the

 

 

conferences.

 

 

The tone used to notify that the cascading link connection has been

 

 

established cannot be customized.

 

 

Default value: NO.

 

 

The tone volume is controlled by the same flag as the IVR messages and

 

 

tones: IVR_MESSAGE_VOLUME.

 

 

 

 

 

CELL_IND_LOCATION

Change the location of the display of Network Quality Indicators displayed

 

 

in the cells of the conference Video Layout.

 

 

Default: TOP_RIGHT

 

 

Range:

 

 

BOTTOM_LEFT

 

 

BOTTOM_RIGHT

 

 

TOP_LEFT

 

 

TOP_RIGHT

 

 

 

 

 

CFG_KEY_ENABLE_FLOW_CONT

Used to enable or disable sending a re-INVITE to endpoints to adjust their

 

ROL_REINVITE

data rate. When set to YES, re-INVITE is used for endpoints that do not

 

 

support flow control in SIP using either the Information or RTCP Feedback

 

 

mechanisms.

 

 

Default: NO.

 

 

 

 

 

CONF_GATHERING_DURATION_S

The value of this System Flag sets the duration of the Gathering Phase in

 

ECONDS

seconds. The Gathering Phase duration of the conference is measured

 

 

from the scheduled start time of the conference.

 

 

Range: 0 - 3600

 

 

Default: 180

 

 

For more information see Video Preview (AVC Participants Only)

 

 

 

 

 

CP_REGARD_TO_INCOMING_SE

For use in the Avaya Environment.

 

TUP_RATE

If set to YES, the RealPresence Collaboration Server calculates the line

 

 

rate for incoming calls in CP conferences, according to the line rate which is

 

 

declared by the endpoint in the H.225 setup message.

 

 

If set to NO, the rate is calculated according to the conference line rate

 

 

regardless of the rate in the H.225 setup message.

 

 

Default: YES.

 

 

 

 

 

CPU_BONDING_LINK_MONITORI

Used when using the MII Monitor for troubleshooting networks.This flag

 

NG_FREQUENCY

sets the MII Polling Interval in milliseconds. A value of zero disables MII

 

 

monitoring.

Default: 100

Polycom®, Inc.