System Configuration Flags

 

 

 

 

Manually Added, Modified, Deleted System Flags

 

 

 

 

Flag

Description

 

 

 

 

 

 

PASSWORD_FAILURE_LIMIT

The number of unsuccessful Logins permitted in Ultra Secure Mode.

 

 

Default: 3

 

 

 

 

 

PCM_FECC

Determines whether the DTMF Code, ##, the Far/Arrow Keys (FECC) or

 

 

both will activate the PCM interface. This flag can be also be used in

 

 

combination with DTMF code definitions to disable PCM.

 

 

Possible Values: YES / NO

 

 

Default: YES.

 

 

 

 

 

PCM_LANGUAGE

Determines the language of the PCM interface.

 

 

Possible Values are: ENGLISH, CHINESE_SIMPLIFIED,

 

 

CHINESE_TRADITIONAL, JAPANESE, GERMAN, FRENCH, SPANISH,

 

 

KOREAN, PORTUGUESE, ITALIAN, RUSSIAN, NORWEGIAN

 

 

Default: Current Collaboration Server Web Client language.

 

 

 

 

 

PORT_GAUGE_ALARM

When set to YES, if system resource usage reaches the High Port Usage

 

 

Threshold as defined for the Port Gauges, System Alerts in the form of an

 

 

Active Alarm and an SNMP trap are generated.

 

 

 

 

 

PRESERVE_ICE_CHANNEL_IN_C

When set to NO (default), local the ICE channel is closed after applying

 

ASE_OF_LOCAL_MODE

CAC bandwidth management when Call Admission Control is enabled in

 

 

the local network.

 

 

When set to YES, the ICE channel is preserved open throughout the call.

 

 

Default: NO

 

 

 

 

 

PRESERVE_PARTY_CELL_ON_F

Used to prevent reassignment of cells in a forced layout that were assigned

 

ORCE_LAYOUT

to endpoints that have disconnected, paused their video, or have been

removed from the conference. The cell will remain black until the endpoint reconnects or a new layout is used, or the conference ends.

Range: YES / NO

Default: NO

NO - Cells of dropped endpoints are reassigned. Endpoints that reconnect will be treated as new endpoints.

YES - Cells of dropped endpoints are not reassigned, but will be reserved until the endpoint reconnects.

Forced Layout Guidelines:

It is recommended that this flag be set to YES if the Collaboration Server is used primarily for ITP conferences with MLA.

When a new forced layout is sent to the MCU, the MCU no longer preserves the cells for disconnected participants. The layout is redrawn using the currently connected participants only.

If the dropped endpoint was forced to use a particular cell, and that cell is switched from forced layout to automatically assigned, the MCU no longer preserves the cell. Any other endpoint can be assigned that particular cell.