Installing the Mail System

Connecting to the Remote Maintenance Device

(Front View)

(Back View)

REMOTE MAINTENANCE DEVICE Mk III

DC

On/Off

RS–232–C

Telephone

Power In

Switch

Port

Line Port

 

 

 

 

Figure 2-6. Remote Maintenance Device

1.Use the modem cable provided to connect the RS-232-C port on the Remote Maintenance Device (see Figure 2-6) to the COM1 port on the system unit (see Figure 2-5).

2.Use a modular telephone cord to connect the Telephone Line Port on the Remote Maintenance Device (see Figure 2-6) to an extension jack on the 206 module. Refer to Communications System Planning Form B1 for the correct extension number.

3.Attach one end of the power cord to the DC Power In jack on the Remote Maintenance Device (see Figure 2-6) and plug the other end into a grounded AC electrical source.

4.Turn on the on/off switch (see Figure 2-6). Verify that the AA, TR, and MR LEDs on the front of the Remote Maintenance Device are lit.

5.Turn off the Remote Maintenance Device.

6.Write the 206 module extension jack number on a label and affix the label to the Remote Maintenance Device. Keep the extension jack number handy. You may need it if the mail system needs servicing.

Security Alert:

Keep the Remote Maintenance Device turned off unless your mail system needs servicing and service personnel need remote access to your system.

Installation 2-9