6-118
Cisco MGX 8850 Routing Switch Command Reference
Release 2.0, Part Number 78-10467-04 Rev C0, October 2001
Chapter6 Logical Node, Port, and Signaling Commands
uppnport
Example
Check for any downed ports by executing dsppnports. Use uppnport to up any por ts that are down. The output of dsppnports shows that only one user port exists (not the 7.3x ports, the first two of which are the BITS clock ports).
8850_NY.8.PXM.a > dsppnports
Summary of total connections
(p2p=point to point,p2mp=point to multipoint,SpvcD=DAX spvc,SpvcR=Routed spvc)
Type #Svcc: #Svpc: #SpvcD: #SpvpD: #SpvcR: #SpvpR: #Total:
p2p: 0 0 0 0 0 0 0
p2mp: 0 0 0 0 0 0 0
Total= 0/50000
Summary of total configured SPVC endpoints
Type #SpvcR #SpvpR #SpvcD #SpvpD Total
p2p: 0 0 0 0 0
p2mp: 0 0 0 0 0
Total=0
Per-port status summary
PortId LogicalId IF status Admin status ILMI state #Conns
7.35 17251107 up up Undefined 0
7.36 17251108 up up Undefined 0
7.37 17251109 up up Undefined 0
7.38 17251110 up up Undefined 0
3:1.1:1 16979969 down down Disable 0
8850_NY.8.PXM.a >
SanJose.7.PXM.a > uppnport 3:1.1:1
Check the administrative status of 3:1.1:1.
8850_NY.8.PXM.a > dsppnport 3:1.1:1
Port: 3:1.1:1 Logical ID: 16979969
IF status: up Admin Status: up
UCSM: enable
Auto-config: enable Addrs-reg: enable
IF-side: network IF-type: uni
UniType: private Version: uni3.1
PassAlongCapab: n/a
Input filter: 0 Output filter: 0
minSvccVpi: 0 maxSvccVpi: 4095
minSvccVci: 35 maxSvccVci: 65535
minSvpcVpi: 1 maxSvpcVpi: 4095