9-105
Cisco MGX 8850 Routing Switch Command Reference
Release 2.0, Part Number 78-10467-04 Rev C0, October 2001
Chapter9 Troubleshooting Commands dspenvalms
Power Supply A1 none None none Normal
Power Supply A2 none None none Normal
Power Supply A3 none None none Normal
DC Voltage A 42 to 54 VoltsDC 49 Normal
Power Supply B1 none None none Missing
Power Supply B2 none None none Missing
Power Supply B3 none None none Missing
DC Voltage B 42 to 54 VoltsDC 0 Normal
Top Fan Tray 1 >= 2000 RPM 3504 Normal
Top Fan Tray 2 >= 2000 RPM 3498 Normal
Top Fan Tray 3 >= 2000 RPM 3576 Normal
Top Fan Tray 4 >= 2000 RPM 3498 Normal
Top Fan Tray 5 >= 2000 RPM 3480 Normal
Top Fan Tray 6 >= 2000 RPM 3570 Normal
Top Fan Tray 7 >= 2000 RPM 3468 Normal
Top Fan Tray 8 >= 2000 RPM 3366 Normal
Top Fan Tray 9 >= 2000 RPM 3444 Normal
Bottom Fan Tray 1 >= 2000 RPM 0 Missing
Bottom Fan Tray 2 >= 2000 RPM 0 Missing
Bottom Fan Tray 3 >= 2000 RPM 0 Missing
Bottom Fan Tray 4 >= 2000 RPM 0 Missing
Bottom Fan Tray 5 >= 2000 RPM 0 Missing
Bottom Fan Tray 6 >= 2000 RPM 0 Missing
Bottom Fan Tray 7 >= 2000 RPM 0 Missing
Bottom Fan Tray 8 >= 2000 RPM 0 Missing
Bottom Fan Tray 9 >= 2000 RPM 0 Missing
+5V Input 4.850^ to 5.150^ VoltsDC 5.017 Informational
+3.3V Input 3.200^ to 3.400^ VoltsDC 3.259 Informational
+2.5V Input 2.425^ to 2.575^ VoltsDC 2.440 Informational
Calibration VDC 0x7e^ to 0x82^ Other 0x80 Informational