Verifying the Overall Status of the Fabric Interconnects
Procedure
Step 1 Inthe Navigation pane, clickthe Equipment tab.
Step 2 Onthe Equipment tab, expand Equipment >Fabric Interconnects.
Step 3 Clickthe node for the fabric interconnect that you want to verify.
Step 4 Inthe Work pane, click the General tab.
Step 5 Inthe Status area, verify thatthe Overall Status isoperable.
Ifthe statusis not operable,create and download a Tech Support file, and contact Cisco Technical Support.
Donot proceedwith the firmware upgrade. For more information about Tech Support files, see the Cisco
UCSManager B-SeriesTroubleshooting Guide.
Verifying the High Availability Status and Roles of a Cluster Configuration
Thehigh availability status is the same for both fabric interconnects in a cluster configuration.
Procedure
Step 1 Inthe Navigation pane, clickthe Equipment tab.
Step 2 Onthe Equipment tab, expand Equipment >Fabric Interconnects.
Step 3 Clickthe node for one of thefabric interconnects in the cluster.
Step 4 Inthe Work pane, click the General tab.
Step 5 Ifthe fields in the High Availability Details area are not displayed, click the Expand icon to the right of the
heading.
Step 6 Verifythat the following fields display the following values:
Required ValueField Name
YesReadyfield
UpStatefield
Ifthe values are different, create and download a Tech Support file, and contact Cisco Technical Support. Do
notproceed with the firmware upgrade. For more information about Tech Support files, see the Cisco UCS
ManagerB-Series Troubleshooting Guide.
Step 7 Notethe value in the Leadership field to determine whether the fabric interconnect is the primary or
subordinate.
Youneed to know this information to upgrade the firmware on the fabric interconnects.
Cisco UCS Manager GUI Configuration Guide, Release 2.0
202 OL-25712-04
Completing the Prerequisites for Upgrading the Firmware