Server Power State After
Communication Is Disrupted
Current Server Power StateDesired Power State in Service
Profile
PoweredOn
Runningservers are not
shutdown regardlessof
thedesired power state in
theservice profile.
Note
PoweredOnDown
Reacknowledging a Blade ServerPerformthe following procedure if you need to have Cisco UCS Manager rediscover the server and all
endpointsin the server. For example, you can use this procedure if a server is stuck in an unexpected state,
suchas the discovery state.
Procedure
Step 1 Inthe Navigation pane, clickthe Equipment tab.
Step 2 Onthe Equipment tab, expand Equipment >Chassis >Chassis Number >Servers.
Step 3 Choosethe server that you wantto acknowledge.
Step 4 Inthe Work pane, click the General tab.
Step 5 Inthe Actions area, clickServer Maintenance.
Step 6 Inthe Maintenance dialog box, do the following:
a) Click Re-acknowledge.
b) Click OK.
CiscoUCS Manager disconnects the server and then builds the connections between the server and the fabric
interconnector fabric interconnects in the system. The acknowledgment may take several minutes to complete.
Afterthe server has been acknowledged, the Overall Status field on the General tab displaysan OK status.
Removing a Server from a ChassisBefore You Begin
Physicallyremove the server from its chassis before performing the followingprocedure.
Cisco UCS Manager GUI Configuration Guide, Release 2.0
OL-25712-04 591
Reacknowledging a Blade Server