Procedure
Step 1 Inthe Navigation pane, clickthe SAN tab.
Step 2 Inthe SAN tab, expandSAN >SAN Cloud.
Step 3 Right-clickSAN Pin Groups and select Create SAN Pin Group.
Step 4 Entera unique name and description for the pin group.
Step 5 Topin traffic for fabric interconnect A, do the following in the Targets area:
a) Check the Fabric A check box.
b) Click the drop-down arrow on the Interface field and navigate through the tree-style browser to select
theuplink Fibre Channel port you want to associate with the pin group.
Step 6 Topin traffic for fabric interconnect B, do the following in the Targets area:
a) Check the Fabric B check box.
b) Click the drop-down arrow on the Interface field and navigate through the tree-style browser to select
theuplink Fibre Channel port you want to associate with the pin group.
Step 7 ClickOK.
What to Do Next
Includethe pin group in a vHBA template.
Deleting a SAN Pin Group
Procedure
Step 1 Inthe Navigation pane, clickthe SAN tab.
Step 2 Inthe SAN tab, expandSAN >SAN Cloud >SAN PinGroups.
Step 3 Right-clickthe SAN pin group you want to delete and select Delete.
Step 4 Ifthe CiscoUCS Manager GUI displaysa confirmation dialog box, clickYes.
Cisco UCS Manager GUI Configuration Guide, Release 2.0
344 OL-25712-04
Deleting a SAN Pin Group