PortChannel—All links from an IOM to a fabric interconnect are grouped in a port channel.
Global—Thechassis inherits this configuration from the chassis discovery policy. This is the default
value.
Step 6 ClickSave Changes.
Configuring the Rack Server Discovery Policy

Rack Server Discovery Policy

Therack server discovery policy determines how the system reacts when you add a new rack-mount server.
CiscoUCS Manager uses the settings in the rack server discovery policy to determine whether any data on
thehard disks arescrubbed and whether server discovery occurs immediately or needs to wait for explicit
useracknowledgement.
CiscoUCS Manager cannot discover any rack-mount server that has not been correctly cabled and connected
tothe fabric interconnects. For information about how to integrate a supported Cisco UCS rack-mount server
withCisco UCS Manager, see the hardware installation guide for that server.

Configuring the Rack Server Discovery Policy

Procedure
Step 1 Inthe Navigation pane, clickthe Equipment tab.
Step 2 Onthe Equipment tab, click the Equipment node.
Step 3 Inthe Work pane, click the Policies tab.
Step 4 Clickthe Global Policiessubtab.
Step 5 Inthe Rack ServerDiscovery Policy area, complete the followingfields:
DescriptionName
Theway the system reacts when you add a new rack-mount server. This
canbe one of the following:
Immediate—Thesystem attempts to discovernew servers
automatically
UserAcknowledged—The system waits until the user tellsit to
searchfor new servers
Actionfield
Thescrub policy to run on a newly discovered server if that server meets
thecriteria in the selected server pool policy qualification.
ScrubPolicy drop-down list
Cisco UCS Manager GUI Configuration Guide, Release 2.0
244 OL-25712-04
Configuring the Rack Server Discovery Policy