Resetting the CMOS for a Rack-Mount Server
Onrare occasions, troubleshooting a server may require you to reset the CMOS. This procedure is not part
ofthe normal maintenance of a server.
Procedure
Step 1 Inthe Navigation pane, clickthe Equipment tab.
Step 2 Onthe Equipment tab, expand Equipment >Rack Mounts >Servers.
Step 3 Choosethe server for which you wantto resetthe CMOS.
Step 4 Inthe Work pane, click the General tab.
Step 5 Inthe Actions area, clickRecover Server.
Step 6 Inthe Recover Server dialogbox, do the following:
a) Click Reset CMOS.
b) Click OK.
Resetting the CIMC for a Rack-Mount Server
Onrare occasions, such as an issue with the current running firmware, troubleshooting a server may require
youto reset the CIMC. This procedure is not part of the normal maintenance of a server. After you reset the
CIMC,the server boots with the running version of thefirmware for that server.
Procedure
Step 1 Inthe Navigation pane, clickthe Equipment tab.
Step 2 Onthe Equipment tab, expand Equipment >Rack Mounts >Servers.
Step 3 Choosethe server for which you wantto resetthe CIMC.
Step 4 Inthe Work pane, click the General tab.
Step 5 Inthe Actions area, clickRecover Server.
Step 6 Inthe Recover Server dialogbox, do the following:
a) Click Reset CIMC (Server Controller).
b) Click OK.