Supported Cisco UCS Servers
ThroughCisco UCS Manager, you can monitor disk drives for the following servers:
• B-200 blade server
• B-230 blade server
• B-250 blade server
• B-440 blade server
CiscoUCS Manager cannot monitor disk drives inany otherblade server or rack-mountserver.
Storage Controller Firmware Level
Thestorage controller on a supported server must have LSI 1064E firmware.
CiscoUCS Manager cannot monitor disk drives in servers with a different level of storage controller firmware.
Prerequisites for Disk Drive Monitoring
Inaddition to the supported servers and storage controller firmware version, you must ensure that the following
prerequisiteshave been met for disk drive monitoring to provide useful status information:
• The drive must be inserted in the server drive bay.
• The server must be powered on.
• The server must have completed discovery.
• The results of the BIOS POST complete must be TRUE.
Viewing the Status of a Disk Drive
Procedure
Step 1 Inthe Navigation pane, clickthe Equipment tab.
Step 2 Onthe Equipment tab, expand Equipment >Chassis >Chassis Number >Servers.
Step 3 Clickthe server for which you wantto view the status of thedisk drive.
Step 4 Inthe Work pane, click the Inventory tab.
Step 5 Clickthe Storage subtab.
Step 6 Clickthe down arrows to expand the Disks bar andview the following fields in the States section for each
diskdrive:
Cisco UCS Manager GUI Configuration Guide, Release 2.0
OL-25712-04 659
Server Disk Drive Monitoring