Nortel Networks 2300 Series manual Clear system ip-address, Clear timezone

Models: 2300 Series

1 622
Download 622 pages 48.74 Kb
Page 116
Image 116

116IP Services Commands

show timedate on page 161

show timezone on page 161

clear system ip-address

Clears the system IP address.

Caution! Clearing the system IP address disrupts the system tasks that use the address.

Syntax clear system ip-address

Defaults None.

Access Enabled.

Usage Clearing the system IP address can interfere with system tasks that use the system IP address, including the following:

Mobility Domain operations

Topology reporting for dual-homed APs

Default source IP address used in unsolicited communications such as AAA accounting reports and SNMP traps

Examples To clear the system IP address, type the following command:

WSS# clear system ip-address

success: change accepted.

See Also

set system ip-address on page 141

show system on page 68

clear timezone

Clears the time offset for the WSS’s real-time clock from Coordinated Universal Time (UTC). UTC is also know as Greenwich Mean Time (GMT).

Syntax clear timezone

Defaults None.

Access Enabled.

Examples To return the WSS’s real-time clock to UTC, type the following command:

WSS# clear timezone

success: change accepted.