Nortel Networks 2300 Series manual Show tech-support

Models: 2300 Series

1 622
Download 622 pages 48.74 Kb
Page 80
Image 80

80System Services Commands

 

Table 1: show system output (continued)

 

 

Field

Description

 

 

PSU Status

Status of the lower and upper power supply units:

 

missing—Power supply is not installed or is inoperable.

 

• DC ok—Power supply is producing DC power.

 

• DC output failure—Power supply is not producing DC power.

 

WSS Software sends an alert to the system log every 5 minutes

 

until this condition is corrected.

 

• AC ok—Power supply is receiving AC power.

 

• AC not present—Power supply is not receiving AC power.

 

 

Memory

Current size (in megabytes) of nonvolatile memory (NVRAM) and synchronous

 

dynamic RAM (SDRAM), plus the percentage of total memory space in use, in

 

the following format:

 

NVRAM size /SDRAM size (percent of total)

 

 

Total Power Over

Total power that the WSS is currently supplying to its directly connected APs, in

Ethernet

watts.

 

 

See Also

clear system on page 55

set system contact on page 62

set system countrycode on page 63

set system idle-timeout on page 64

set system ip-address on page 65

set system location on page 65

set system name on page 66

show tech-support

Provides an in-depth snapshot of the status of the WSS, which includes details about the boot image, the version, ports, and other configuration values. This command also displays the last 100 log messages.

Syntax show tech-support [file [subdirname/]filename]

[subdirname/]filename

Optional subdirectory name, and a string up to 32 alphanumeric

 

 

characters. The command’s output is saved into a file with the

 

 

specified name in nonvolatile storage.

Defaults

None.

 

Access

Enabled.

 

NN47250-100 (Version 02.51)

Page 80
Image 80
Nortel Networks 2300 Series manual Show tech-support