System Services Commands 79

 

 

 

 

Table 1: show system output

 

 

 

Field

Description

 

 

 

Product Name

WSS model number.

 

 

 

System Name

System name (factory default, or optionally configured with set system name).

 

 

 

System Countrycode

Country-specific 802.11 code required for AP operation (configured with set

 

system countrycode).

 

 

 

System Location

Record of WSS’s physical location (optionally configured with set system

 

location).

 

 

 

System Contact

Contact information about the system administrator or another person to contact

 

about the system (optionally configured with set system contact).

 

 

 

System IP

Common interface, source, and default IP address for the WSS, in dotted decimal

 

notation (configured with set system ip-address).

 

 

 

System idle timeout

Number of seconds WSS Software allows a CLI management session (console,

 

Telnet, or SSH) to remain idle before terminating the session. (The system idle

 

timeout can be configured using the set system idle-timeoutcommand.)

 

 

 

System MAC

WSS media access control (MAC) machine address set at the factory, in 6-byte

 

hexadecimal format.

 

 

 

Boot Time

Date and time of the last system reboot.

 

 

 

Uptime

Number of days, hours, minutes, and seconds that the WSS has been operating

 

since its last restart.

 

 

 

Fan status

Operating status of the three WSS cooling fans:

 

OK—Fan is operating.

 

Failed—Fan is not operating. WSS Software sends an alert to

 

the system log every 5 minutes until this condition is

 

corrected.

 

Fan 1 is located nearest the front of the chassis, and fan 3 is located nearest the

 

back.

 

 

 

Temperature

Status of temperature sensors at three locations in the WSS:

 

ok—Temperature is within the acceptable range of 0° C to

 

50° C (32° F to 122° F).

 

Alarm—Temperature is above or below the acceptable range.

 

WSS Software sends an alert to the system log every 5 minutes

 

until this condition is corrected.

 