Image 294

294AP Commands

History Introduced in WSS Software Version 3.0.

Examples The following command sets the power interval for radios in radio profile rp2 to 240 seconds:

WSS# set radio-profile rp2 auto-tune power-interval 240

success: change accepted.

See Also

set ap radio auto-tunemax-power on page 265

set radio-profileauto-tunepower-config on page 282

set radio-profileauto-tunepower-lockdown on page 284

set radio-profileauto-tunepower-lockdown on page 284

set radio-profileauto-tunepower-ramp-interval on page 285

show service-profile on page 380

set radio-profile auto-tune power-lockdown

Locks down the current power settings on all radios in a radio profile. The power settings that are in effect when the command is entered are changed into statically configured power settings on the radios. RF Auto- Tuning of power is then disabled in the radio profile.

Syntax set radio-profile name auto-tune power-lockdown

name

Radio profile name.

Defaults By default, when RF Auto-Tuning of power is enabled, power settings continue to be changed dynamically based on network conditions.

Access Enabled.

History Introduced in WSS Software Version 5.0.

Usage To save this command and the static power configuration commands created when you enter this command, save the configuration.

Examples The following command locks down the power settings for radios in radio profile rp2:

WSS# set radio-profile rp2 auto-tune power-lockdown

success: change accepted.

See Also

set ap radio auto-tunemax-power on page 265

set radio-profileauto-tunechannel-lockdown on page 282

set radio-profileauto-tunepower-config on page 282

set radio-profileauto-tunepower-interval on page 283

set radio-profileauto-tunepower-ramp-interval on page 285

show radio-profile on page 376

NN47250-100 (Version 02.51)