2.3 MELSEC-QnA/Q/QS, MELDAS C6 *

The device ranges that can be set when selecting

[MELSEC-QnA/Q/QS, MELDAS C6*]*13 as the controller type are as follows.

 

Device name*7 *8 *12

 

Setting range

Device No.

 

 

representation

 

 

 

 

 

 

 

 

Input (X)

 

X0

to

X3FFF

Hexadecimal

 

 

 

 

 

 

 

 

Output (Y)

 

Y0

to

Y3FFF

 

 

 

 

 

 

 

 

 

 

Internal relay (M)*9

M0

to

M32767

 

 

Latch relay (L)

L0

to

L32767

Decimal

 

 

 

 

 

 

 

Annunciator (F)

F0

to

F32767

 

 

 

 

 

 

 

 

 

Link relay (B)

 

B0

to

B7FFF

Hexadecimal

 

 

 

 

 

 

 

 

 

Timer*9

 

Contact (TT)

TT0

to

TT32767

 

 

 

 

 

 

 

 

 

 

Coil (TC)

TC0

to

TC32767

 

 

 

 

 

 

 

 

 

 

 

 

 

device

Counter*9

 

Contact (CT)

CT0

to

CT32767

 

 

 

 

 

 

 

 

Coil (CC)

CC0

to

CC32767

Decimal

 

 

 

 

 

 

 

 

Special relay (SM)

SM0

to

SM2047

 

Bit

 

 

 

 

 

 

 

 

 

Retentive

 

Contact (SS)

SS0

to

SS32767

 

 

timer*9

 

 

 

 

 

 

 

 

Coil (SC)

SC0

to

SC32767

 

 

Step relay (S)

S0

to

S32767

 

 

 

 

 

 

 

 

Link special relay (SB)

SB0

to

SB7FFF

Hexadecimal

 

 

 

 

 

 

 

 

 

 

Specified bit of the

 

 

 

 

 

following word devices

 

 

Word device bit

(Except Timer, Counter,

 

Retentive timer, Index

 

 

 

 

 

 

 

 

 

register and Buffer

 

 

 

 

 

 

memory)

 

 

 

 

 

 

 

 

Data register (D)*9

D0

to

D32767

Decimal

 

Special data register (SD)

SD0

to

SD2047

 

 

 

 

 

 

 

 

 

Link register (W)

W0

to

W7FFF

Hexadecimal

 

 

 

 

 

 

 

Timer (current value) (TN)*9

TN0

to

TN32767

 

 

Counter (current value)

CN0

to

CN32767

 

 

(CN)*9

 

Decimal

 

 

 

 

 

 

Retentive timer

SN0

to

SN32767

 

 

(current value) (SN)*9

 

 

 

 

 

 

 

Link special register (SW)

SW0

to

SW7FFF

Hexadecimal

 

 

 

 

 

 

 

File register (R)*1*2

R0

to

R32767

 

 

Extension

 

Block

0

to

255

 

 

file register

 

 

 

 

 

 

device

 

Device

R0

to

R32767

 

(ER)*1*10*11

 

 

 

 

 

 

 

 

Extension file register

ZR0

to

ZR1042431

 

Word

(ZR)*1*3*4*10*11

 

 

 

 

 

 

 

 

 

 

 

Decimal

Index register (Z)

Z0

to

Z15

 

 

 

 

 

 

 

 

Buffer memory

 

 

 

 

 

(Intelligent function module)

BM0

to

BM32767

 

 

(BM)*5*10*11

 

 

 

 

 

 

Buffer memory

 

 

 

 

 

(Intelligent function module)

G0

to

G65535

 

 

(G)*4*5*10*11

 

 

 

 

 

 

Ww*10*11

 

Ww0

to

Ww1FFF

Hexadecimal

 

Wr*10*11

 

Wr0

to

Wr1FFF

 

 

 

 

 

 

 

Converting the above bit

 

 

Bit device word*6*10

devices into words

 

(Except Timer, Counter

 

 

 

 

 

 

 

 

 

and Retentive timer)

 

 

 

 

 

 

 

 

 

*1 Do not set a file register by GT Designer3 when executing multiple programs with the file of the file register set at [Use the same file name as the program] by the PLC parameter of GX Developer.(Except MELSEC-QnA)

Otherwise, read/write at GOT will be erroneous.

*2 Available for file register of block No. switched with the RSET instruction.

*3 Available for file register of block No. of file name switched with the QDRSET instruction.

*4 GOT treats them in units of 32k (32768 points).

*5 Only the intelligent function module on the station connected to GOT can be specified.

Set within the address range of the buffer memory existing in the target intelligent function module.

*6 The device No. must be set in multiples of 16.

*7 When monitoring MELDAS C6/64, if a word device outside the range is set, the value becomes indefinite.

When a bit device outside the range is set, the object may not be displayed or the set function may fail to operate. Check the set device using the device list of GT Designer3.

*8 Devices used by the MELDAS C6/64 system cannot be used.

*9 Do not use local devices set in the MELSEC-Q system. Otherwise, normal monitoring is not performed.

*10 This is not supported by GT10.

*11 This cannot be monitored when in GOT multi-drop connection.

*12 Only reading is possible from QS001CPU.

*13 For GT14, GT11 and GT10, the controller type is as follows.

GT14, GT11: MELSEC-QnA/Q, MELDAS C6 *

GT10: MELSEC-QnA/Q

2 - 10

2. DEVICE RANGE THAT CAN BE SET

 

2.3 MELSEC-QnA/Q/QS, MELDAS C6 *