RS422 connection diagram 8)

(For GT16, GT15, GT14, GT12, GT11, GT105, GT104 )

GOT side*2

RDA 2

RDB 7

SDA 1

SDB 6

RSA 3

RSB 8

CSA 4

CSB 9

SG 5

FG -

FR-E7TR side

FR-E7TR side

FR-E7TR side

terminal block

terminal block

terminal block*1

Station No.0

Station No.1

Station No.2

 

 

SDA

SDA

 

 

 

 

SDA

 

 

 

 

 

 

 

 

SDB

SDB

 

 

 

 

SDB

 

 

 

 

 

 

 

 

RDA

RDA

 

 

 

 

RDA

 

 

 

 

 

 

 

 

RDB

RDB

 

 

 

 

RDB

 

 

 

 

 

 

SDB

 

 

 

 

SDB

 

 

SDB

 

 

 

 

 

 

SDA

 

 

 

 

SDA

 

 

SDA

 

 

 

 

 

 

RDB

 

 

 

 

RDB

 

 

RDB

 

 

 

 

 

 

RDA

 

 

 

 

RDA

 

 

RDA

 

 

 

 

 

 

 

 

SG

SG

 

 

 

 

SG

 

 

 

 

 

 

SG

 

 

 

 

SG

 

 

SG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 Turn ON (100 ) the terminator switch for the most distant FR-E7TR from the GOT.

*2 For GT16, GT15 and GT12, set the terminating resistor of GOT side, which will be a terminal, to "Enable". For GT14, GT11 and GT10, set the terminating resistor of GOT side, which will be a terminal, to "330 ".

1.4.3 Terminating resistors of GOT

RS422 connection diagram 9)

Distributor side

 

 

 

SDA

5

 

 

 

 

SDB

4

 

Terminating resistor

 

100Ω 1/2W

 

 

 

RDA

3

 

 

 

 

RDB

6

 

 

 

 

P5S

2

 

 

 

 

P5S

8

 

 

 

 

SG

1

 

 

 

 

 

 

 

 

 

 

RS422 connection diagram 10) (For GT1030, GT1020)

GOT side*1

Inverter side or distributor side

(terminal block)

(Modular connector)

 

 

 

 

 

RDA

SDA

 

 

 

 

3

 

 

 

 

SDB

 

 

 

 

6

RDB

 

 

 

 

RDA

 

 

 

 

5

SDA

 

 

 

 

RDB

 

 

 

 

4

SDB

 

 

 

 

SG

 

 

 

 

1

SG

 

 

 

 

RSA

 

 

 

 

2

P5S

RSB

 

 

 

 

7

SG

CSA

 

 

 

 

8

P5S

CSB

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 Set the terminating resistor of the GOT side to "330". 1.4.3 Terminating resistors of GOT

RS422 connection diagram 11) (For GT1030, GT1020)

GOT side*2

 

FR-A5NR side

(terminal block)

 

(terminal block)

 

 

 

 

 

 

 

 

 

 

 

 

SDA

 

 

 

 

 

 

 

 

RDA

 

 

 

 

 

 

 

 

SDB

 

 

 

 

 

 

 

 

RDB

 

 

 

 

 

 

 

 

RDA

 

 

 

 

 

 

SDA

 

 

 

 

 

 

RDB

 

 

 

 

 

 

SDB

 

 

 

 

 

 

SG

 

 

 

 

 

 

 

SG

 

 

 

 

 

 

 

RSA

*1

 

 

 

 

RDR

 

 

 

 

 

 

 

 

 

 

 

RSB

 

 

 

 

 

 

CSA

CSB

*1 Connect a terminating resistor jumper to RDB and RDR. The terminating resister jumper is packed together with the FR-A5NR.

*2 Set the terminating resistor of the GOT side to "330". 1.4.3 Terminating resistors of GOT

15 - 24

15. INVERTER CONNECTION

 

15.3 Connection Diagram