Expansion unit settings

(1)FCU6-EX879 (Optical fiber cable)

No.

Switch name

 

 

 

 

Settings

 

 

 

 

 

 

Condition setting

Set the operation condition.

 

 

 

 

 

 

 

 

 

 

switch

 

 

 

 

 

 

 

 

 

 

 

 

 

SW

Description

 

OFF

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Network type*1

 

Inter-PC net (PC)

 

 

Remote I/O net

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Station type*4

 

Normal station (N.ST)

 

Control station (MNG)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

3

Used parameter*2

 

Common parameters (PRM)

Default parameter (D.PRM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)

 

 

 

 

5

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Number of stations*2

 

OFF

8

 

ON

16

OFF

32

ON

64

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

5

(Valid when SW3 is ON)

 

OFF

Station

 

OFF

Station

ON

Station

ON

Station

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

B/W total points*2

 

OFF

2K

 

ON

4K

OFF

6K

ON

8K

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

(Valid when SW3 is ON)

 

OFF

points

 

OFF

points

ON

points

ON

points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Not used

 

Always OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Station number

 

 

 

 

 

 

 

 

 

 

 

 

 

setting switch

Station number setting*2*3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2)

 

 

 

 

 

 

 

 

(Setting range)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01 to 64: Station number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other than 01 to 64: Setting error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting switch of

 

 

 

 

 

 

 

 

 

 

 

 

 

group number

 

 

 

 

 

 

 

 

 

 

 

 

3)

 

 

 

 

 

 

 

 

Group number setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not used, fixed to 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting switch of

 

 

 

 

 

 

 

 

 

 

 

 

 

network number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Network number setting*2

 

 

 

 

 

 

 

 

 

4)

 

 

 

 

 

 

 

 

(Setting range)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

001 to 255: Network number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other than 001 to 255: Setting error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode setting switch

Mode setting*2

 

 

 

 

 

 

 

 

 

5)

 

 

 

 

 

 

 

 

0: Online

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1: Cannot be used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2: Offline

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 to F: Test mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 Set the network type to the PLC to PLC network.

*2 Set as necessary.

*3 Set the station No. not to overlap with that of other units.

*4 Set the station type to the control station.

For details of the parameter setting, refer to the following.

C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373

17

ROBOT CONTROLLER CONNECTION

18

CNC CONNECTION

19

CONNECTION

GOT MULTI-DROP

20

MULTIPLE-GT14, GT12, GT11, GT10 CONNECTION FUNCTION

21

FUNCTION

MULTI-CHANNEL

22

FUNCTION

FA TRANSPARENT

18. CNC CONNECTION

18 - 17

18.5 CNC Side Settings