1.3 Option Devices for the Respective Connection

The following shows the option devices to connect in the respective connection type.

For the specifications, usage and connecting procedure on option devices, refer to the respective device manual.

1.3.1Communication module

Product name

Model

 

Specifications

 

GT15-QBUS

For QCPU (Q mode), motion controller CPU (Q series)

 

Bus connection (1ch) unit standard model

 

 

 

 

 

 

GT15-QBUS2

For QCPU (Q mode), motion controller CPU (Q series)

 

Bus connection (2ch) unit standard model

 

 

 

 

 

 

GT15-ABUS

For A/QnACPU, motion controller CPU (A series)

 

Bus connection (1ch) unit standard model

 

 

 

 

 

 

GT15-ABUS2

For A/QnACPU, motion controller CPU (A series)

 

Bus connection (2ch) unit standard model

Bus connection unit

 

 

 

 

 

GT15-75QBUSL

For QCPU (Q mode), motion controller CPU (Q series)

 

 

Bus connection (1ch) unit slim model

 

 

 

 

 

 

GT15-75QBUS2L

For QCPU (Q mode), motion controller CPU (Q series)

 

Bus connection (2ch) unit slim model

 

 

 

 

 

 

GT15-75ABUSL

For A/QnACPU, motion controller CPU (A series)

 

Bus connection (1ch) unit slim model

 

 

 

 

 

 

GT15-75ABUS2L

For A/QnACPU, motion controller CPU (A series)

 

Bus connection (1ch) unit slim model

 

 

 

 

 

 

GT15-RS2-9P

RS-232 serial communication unit (D-sub 9-pin (male))

 

 

 

Serial communication module

GT15-RS4-9S

RS-422/485 serial communication unit (D-sub 9-pin (female))

 

 

 

 

GT15-RS4-TE

RS-422/485 serial communication unit (terminal block)

 

 

 

 

 

RS-422 conversion unit

GT15-RS2T4-9P

RS-232

RS-422 conversion unit

RS-422 side connector 9-pin

 

 

GT15-RS2T4-25P

RS-422 side connector 25-pin

 

 

 

 

 

 

 

MELSECNET/H

GT15-J71LP23-25

Optical loop unit

 

 

 

 

Communication module

GT15-J71BR13

Coaxial bus unit

 

 

 

 

MELSECNET/10

GT15-75J71LP23-Z

Optical loop unit (A9GT-QJ71LP23 + GT15-75IF900 set)

 

 

 

 

Communication module

GT15-75J71BR13-Z

Coaxial bus unit (A9GT-QJ71BR13 + GT15-75IF900 set)

 

 

 

 

 

 

CC-Link IE Controller Network

GT15-J71GP23-SX

Optical loop unit

communication unit

 

 

 

 

 

 

 

 

 

CC-Link IE Field Network

GT15-J71GF13-T2

CC-Link IE Field Network (1000BASE-T) unit

communication unit

 

 

 

 

 

 

 

 

GT15-J61BT13

Intelligent device station unit CC-LINK Ver. 2 compatible

CC-Link communication unit

 

 

 

 

GT15-75J61BT13-Z

Intelligent device station unit

 

 

(A8GT-61BT13 + GT15-75IF900 set)

 

 

 

 

 

Ethernet communication unit

GT15-J71E71-100

Ethernet (100Base-TX) unit

 

 

 

 

 

1

PREPARATORYFORPROCEDURESMONITORING 2

RANGESETBE

DEVICE CANTHAT 3

RANGEACCESS MONITORINGFOR 4

MONITORTOREDUNTANTSYSTEM HOW 5

CONNECTIONBUS 6

DIRECTTOCONNECTIONCPU 7

LINKCOMPUTER CONNECTION 8

ETHERNETCONNECTION

1. PREPARATORY PROCEDURES FOR MONITORING

1 - 17

1.3 Option Devices for the Respective Connection