(b) Station information setting
|
|
|
| Setting |
Item |
| Set value | necessity at | |
| GOT | |||
|
|
|
| |
|
|
|
| connection |
Station type |
| Intelligent device station |
| |
|
| (fixed) |
| |
|
|
|
| |
|
|
|
| |
Exclusive station count*1 |
| Exclusive station 1 |
| |
Reserve/invalid station |
| No setting |
| |
select |
|
| ||
|
|
|
| |
|
|
|
|
|
Intelligent buffer select |
| (Use default value) |
| |
(word) |
|
| ||
|
|
|
| |
|
|
|
|
|
| : Necessary | : As necessary | : Not necessary |
*1 Specify the same number of occupied stations as that of the GOT.
POINT
When changing the network parameter
After writing the network parameter to the PLC CPU, operate the PLC CPU ether turning OFF and then ON or resetting.
(2)Setting from sequence program
The parameter is written to the buffer memory, and the data link is automatically started when PLC CPU status changes from STOP to RUN.
(a) I/O signal of
Control & Communication Link System Master/ Local Module Type AJ61QBT11/A1SJ61QBT11 User's Manual
(b) Device used by user
Device | Application | |
M100, M101 | Flag for parameter setting | |
|
| |
M102, M103 | Flag for data link startup | |
|
| |
D0 | Number of connected modules | |
|
| |
D1 | Number of retry | |
|
| |
D2 | Automatic reconnection station count | |
|
| |
D3 | Operation specification in the case of CPU failure | |
|
| |
D4 | Reserved station specification (Station No. 1 to | |
Station No. 16) | ||
| ||
|
| |
D5 | Error invalid station specification (Station No. 1 to | |
Station No. 16) | ||
| ||
|
| |
D6 | Station data (first module) | |
|
| |
D400 | Error code in the case of data link startup failure | |
|
|
(c)Buffer memory settings used in the present example
Buffer memory |
|
|
| |
address | Item |
| Set value | |
Decimal (Hex) |
|
|
| |
1(11 (1H) | Number of connected modules | 1 | (1 module) | |
|
|
|
| |
2(22 (2H) | Number of retry | 3 | (3times) | |
|
|
|
| |
3(33 (3H) | Automatic reconnection station | 1 | (1 station) | |
count | ||||
|
|
| ||
|
|
|
| |
6(66 (6H) | Operation specification in the | 0 | (stop) | |
case of CPU failure | ||||
|
|
| ||
|
|
|
| |
16(1016 (10H) | Reserved station specification | 0 | (No | |
(Station No. 1 to Station No. 16) | specification) | |||
| ||||
|
|
|
| |
20(1420 (14H) | Error invalid station specification | 0 | (No | |
(Station No. 1 to Station No. 16) | specification) | |||
| ||||
|
|
| ||
32(2032 (20H) | Station data (first module)*1 | 2101H |
*1 Details for the station data are shown below.
For 1) and 2), set the same station No. and number of station occupied as those of the GOT.
For 3), the setting is fixed.
b15 to | b12 b11 | to | b8 b7 | to | b0 | ||
3) |
|
| 2) |
|
| 1) |
|
|
|
|
|
|
|
|
|
1)Station No. (Set the same station No. as that of the GOT) 01H to 40H: Station No. 1 to Station No. 64
2)Number of stations occupied (Set the number of station occupied as that of the GOT)
1H: Exclusive station 1
2H: Exclusive station 2
3H: Exclusive station 3
4H: Exclusive station 4
3)Station type (2H: Set it to intelligent device station)
0H: Remote I/O station
1H: Remote device station
2H: Intelligent device station (Incl. local station)
9
TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)
10
MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
11
12
13
14
15
CONNECTION
INVERTER
16
CONNECTION
SERVO AMPLIFIER
13. | 13 - 29 |
13.4 PLC Side Setting |
|