Device name | Item | Symbol*1 | |
PB60, PB1060 | Model loop gain after gain | PG1B | |
switching | |||
|
| ||
|
|
| |
PB61 to 64, | For manufacturer setting | ― | |
PB1061 to 1064 | |||
|
| ||
|
|
|
*1 For the parameters prefixed by an asterisk (*), setting becomes effective when the power is turned off once and back on after setting the parameter data.
(f) Extension setting parameter
Device name | Item | Symbol*1 | |
PC1, PC1001 | Acceleration time constant | STA | |
PC2, PC1002 | Deceleration time constant | STB | |
PC3, PC1003 | STC | ||
deceleration time constant | |||
|
| ||
|
|
| |
PC4, PC1004 | Torque command time constant | TQC | |
|
|
| |
PC5, PC1005 | Internal speed command 1 | SC1 | |
Internal speed limit 1 | |||
|
| ||
|
|
| |
PC6, PC1006 | Internal speed command 2 | SC2 | |
| |||
Internal speed limit 2 | |||
|
| ||
PC7, PC1007 | Internal speed command 3 | SC3 | |
| |||
Internal speed limit 3 | |||
|
| ||
|
|
| |
PC8, PC1008 | Internal speed command 4 | SC4 | |
Internal speed limit 4 | |||
|
| ||
|
|
| |
PC9, PC1009 | Internal speed command 5 | SC5 | |
| |||
Internal speed limit 5 | |||
|
| ||
PC10, PC1010 | Internal speed command 6 | SC6 | |
| |||
Internal speed limit 6 | |||
|
| ||
|
|
| |
PC11, PC1011 | Internal speed command 7 | SC7 | |
Internal speed limit 7 | |||
|
| ||
|
|
| |
| Analog speed command - |
| |
PC12, PC1012 | Maximum speed | VCM | |
| |||
Analog speed limit - Maximum | |||
|
| ||
| speed |
| |
|
|
| |
PC13, PC1013 | Analog torque command | TLC | |
maximum output | |||
|
| ||
|
|
| |
PC14, PC1014 | Analog monitor 1 output | MOD1 | |
|
|
| |
PC15, PC1015 | Analog monitor 2 output | MOD2 | |
PC16, PC1016 | Electromagnetic brake sequence | MBR | |
output | |||
|
| ||
|
|
| |
PC17, PC1017 | Zero speed | ZSP | |
|
|
| |
PC18, PC1018 | Alarm history clear | *BPS | |
PC19, PC1019 | Encoder output pulse selection | *ENRS | |
|
|
| |
PC20, PC1020 | Station number setting | *SNO | |
|
|
| |
PC21, PC1021 | Communication function selection | *SOP | |
PC22, PC1022 | Function selection | *COP1 | |
|
|
| |
PC23, PC1023 | Function selection | *COP2 | |
|
|
| |
PC24, PC1024 | Function selection | *COP3 | |
PC25, PC1025 | For manufacturer setting | ― | |
|
|
| |
PC26, PC1026 | Function selection | *COP5 | |
|
|
| |
PC27, PC1027 | Function selection | *COP6 | |
PC28, PC1028 | For manufacturer setting | ― | |
|
|
| |
PC29, PC1029 | For manufacturer setting | ― | |
|
|
| |
PC30, PC1030 | Acceleration time constant 2 | STA2 | |
PC31, PC1031 | Deceleration time constant 2 | STB2 | |
|
|
| |
PC32, PC1032 | Command input pulse | CMX2 | |
multiplication numerator 2 | |||
|
| ||
|
|
| |
PC33, PC1033 | Command input pulse | CMX3 | |
multiplication numerator 3 | |||
|
| ||
|
|
| |
PC34, PC1034 | Command input pulse | CMX4 | |
multiplication numerator 4 | |||
|
| ||
|
|
| |
PC35, PC1035 | Internal torque limit 2 | TL2 | |
|
|
| |
PC36, PC1036 | Status display selection | *DMD | |
PC37, PC1037 | Analog speed command offset | VCO | |
| |||
Analog speed limit offset | |||
|
|
Device name | Item | Symbol*1 | |
PC38, PC1038 | Analog torque command offset | TPO | |
Analog torque limit offset | |||
|
| ||
|
|
| |
PC39, PC1039 | Analog monitor 1 offset | MO1 | |
|
|
| |
PC40, PC1040 | Analog monitor 2 offset | MO2 | |
|
|
| |
PC41 to 42, | For manufacturer setting | ― | |
PC1041 to 1042 | |||
|
| ||
|
|
| |
PC43, PC1043 | Error excessive alarm detection | ERZ | |
level | |||
|
| ||
|
|
| |
PC44 to 50, | For manufacturer setting | ― | |
PC1044 to 1050 | |||
|
| ||
|
|
| |
PC51, PC1051 | Forced stop deceleration time | RSBR | |
constant | |||
|
| ||
|
|
| |
PC52, PC1052 | For manufacturer setting | ― | |
|
|
| |
PC53, PC1053 | For manufacturer setting | ― | |
|
|
| |
PC54, PC1054 | Vertical axis freefall prevention | RSUP1 | |
compensation amount | |||
|
| ||
|
|
| |
PC55 to PC59, | For manufacturer setting | ― | |
PC1055 to PC1059 | |||
|
| ||
|
|
| |
PC60, PC1060 | Function selection | *COPD | |
|
|
| |
PC61 to PC80, | For manufacturer setting | ― | |
PC1061 to PC1080 | |||
|
| ||
|
|
|
*1 For the parameters prefixed by an asterisk (*), setting becomes effective when the power is turned off once and back on after setting the parameter data.
(g) I/O setting parameter
Device name | Item | Symbol*1 | |
PD1, PD1001 | Input signal automatic on | *DIA1 | |
selection 1 | |||
|
| ||
|
|
| |
PD2, PD1002 | For manufacturer setting | ― | |
|
|
| |
PD3, PD1003 | Input device selection 1L | *DI1L | |
PD4, PD1004 | Input device selection 1H | *DI1H | |
|
|
| |
PD5, PD1005 | Input device selection 2L | *DI2L | |
|
|
| |
PD6, PD1006 | Input device selection 2H | *DI2H | |
PD7, PD1007 | Input device selection 3L | *DI3L | |
|
|
| |
PD8, PD1008 | Input device selection 3H | *DI3H | |
|
|
| |
PD9, PD1009 | Input device selection 4L | *DI4L | |
PD10, PD1010 | Input device selection 4H | *DI4H | |
|
|
| |
PD11, PD1011 | Input device selection 5L | *DI5L | |
|
|
| |
PD12, PD1012 | Input device selection 5H | *DI5H | |
PD13, PD1013 | Input device selection 6L | *DI6L | |
|
|
| |
PD14, PD1014 | Input device selection 6H | *DI6H | |
|
|
| |
PD15 to 16, | For manufacturer setting | ― | |
PD1015 to 1016 | |||
|
| ||
|
|
| |
PD17, PD1017 | Input device selection 8L | *DI8L | |
|
|
| |
PD18, PD1018 | Input device selection 8H | *DI8H | |
|
|
| |
PD19, PD1019 | Input device selection 9L | *DI9L | |
PD20, PD1020 | Input device selection 9H | *DI9H | |
|
|
| |
PD21, PD1021 | Input device selection 10L | *DI10L | |
|
|
| |
PD22, PD1022 | Input device selection 10H | *DI10H | |
PD23, PD1023 | Output device selection 1 | *DO1 | |
|
|
| |
PD24, PD1024 | Output device selection 2 | *DO2 | |
|
|
| |
PD25, PD1025 | Output device selection 3 | *DO3 | |
PD26, PD1026 | Output device selection 4 | *DO4 | |
|
|
| |
PD27, PD1027 | For manufacturer setting | ― | |
|
|
| |
PD28, PD1028 | Output device selection 6 | *DO6 | |
PD29, PD1029 | Input filter setting | *DIF | |
|
|
| |
PD30, PD1030 | Function selection | *DOP1 | |
|
|
| |
PD31, PD1031 | For manufacturer setting | ― | |
PD32, PD1032 | Function selection | *DOP3 | |
|
|
| |
PD33, PD1033 | For manufacturer setting | ― | |
|
|
| |
PD34, PD1034 | Function selection | *DOP5 | |
PD35 to 48, | For manufacturer setting | ― | |
PD1035 to 1048 | |||
|
|
*1 For the parameters prefixed by an asterisk (*), setting becomes effective when the power is turned off once and back on after setting the parameter data.
9
TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)
10
MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
11
12
13
14
15
CONNECTION
INVERTER
16
CONNECTION
SERVO AMPLIFIER
16. SERVO AMPLIFIER CONNECTION | 16 - 41 |
16.6 Device Range that Can Be Set |
|