(2)Combinations of units that affect the number of available channels
The following are examples of unit combinations that affect the number of available channels.
POINT
Installing a unit on another unit (Checking the unit installation position)
For details on the precautions for installing units on another unit, refer to the following.
1.3.7 Installing a unit on another unit (Checking the unit installation position)
For the installation method of each unit, refer to the User's Manual for the communication unit and option unit you are using.
For the method for installing a unit on another unit, refer to the following. User's Manual of GOT used.
Example 1) To add the printer output (when using a PictBridge compatible printer) and the Ethernet download in a system using the bus connection (1 channel), serial connection (3 channels), and the barcode function
(a)For GT16
Mount the printer unit at the third stage, and use the Ethernet interface built in the GOT. This enables both the printer output of the report function and the Ethernet download.
Serial communication |
|
unit |
|
Serial communication | Serial communication |
unit | unit |
Bus connection unit
Printer unit
Barcode reader
(b)For GT15
Because units can be mounted up to the third stage for GT15, the printer output of the report function and the Ethernet download cannot be used together.
Printer unit
Ethernet communication unit
Serial communication |
|
unit |
|
Serial communication | Serial communication |
unit | unit |
Bus connection unit
Barcode reader
21 - 30 | 21. |