8.2.3Connecting to Display I/F

PLC CPU

CNC

GOT

C70

 

Communication driver

 

 

Connection cable

 

 

Ethernet(MELSEC),Q17nNC,CRnD-700

PLC

 

 

Maximum

GOT

 

Number of connectable

 

Communication

Connection cable*1

segment

 

 

Model name

Option device

Model

equipment

type

 

length*3

 

 

 

 

Twisted pair cable

 

 

*2

 

 

 

10BASE-T

 

- (Built into GOT)

*6

 

 

 

Shielded twisted pair cable (STP) or

 

 

CNC C70

 

 

 

 

 

unshielded twisted pair cable (UTP):

 

 

 

 

(Q173NCCPU)

Ethernet

100m

 

 

16 GOTs for 1 network

Category 3, 4, and 5

 

 

*4*5

 

 

 

 

 

 

100BASE-TX

 

 

 

 

 

 

 

 

 

 

 

 

Shielded twisted pair cable (STP):

 

GT15-J71E71-100

 

 

 

 

Category 5 and 5e

 

 

 

 

 

 

 

 

 

 

 

*1 The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.

Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network system.

Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.

*2 When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching hub and operate in a 10Mbps/100Mbps mixed environment.

For how to check the function version, refer to the following. GT16 User's Manual (Hardware)

*3 A length between a hub and a node.

The maximum distance differs depending on the Ethernet device to be used.

The following shows the number of the connectable nodes when a repeater hub is used.

10BASE-T: Max. 4 nodes for a cascade connection (500m)

100BASE-TX: Max. 2 nodes for a cascade connection (205m)

When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of cascades.

For the limit, contact the switching hub manufacturer.

*4 For the system configuration of the CNC C70, refer to the following manual.

C70 Series SET UP MANUAL

*5 Select [Q17nNC] for [Controller Type] in [Ethernet] of GT Designer3. For [Ethernet] of GT Designer3, refer to the following.

8.3.3 Ethernet setting

*6 GT14 models compatible with Ethernet connection are only GT1455-QTBDE and GT1450-QLBDE.

8 - 12

8. ETHERNET CONNECTION

 

8.2 System Configuration