(2) Ethernet setting
| Item | Set value | |
| Host | * | |
|
|
| |
| N/W No. | 1 | |
|
|
| |
| PLC No. | 2 | |
Ethernet |
|
| |
Type | Q17nNC | ||
setting No.1 | |||
|
| ||
| IP address | 192.168.0.19 | |
|
|
| |
| Port No. | 5001 (fixed) | |
|
|
| |
| Communication | UDP (fixed) | |
|
|
|
POINT
[Controller Setting] and [Ethernet] of GT Designer3
For [Controller Setting] and [Ethernet] of GT Designer3, refer to the following.
8.3.1 Setting communication interface (Communication settings)
Checking communication state of CNC C70
(1)When using the Command Prompt of Windows®. Execute a Ping command at the Command Prompt of Windows®.
(a)When normal communication C:\>Ping 192.168.0.19
Reply from 192.168.0.19: bytes=32 time<1ms TTL=64
(b)When abnormal communication C:\>Ping 192.168.0.19 Request timed out.
(2)When abnormal communication
At abnormal communication, check the followings and execute the Ping command again.
• Mounting condition of CNC C70
• Cable connecting condition
• Switch settings and network parameter settings
• Operation state of PLC CPU (faulty or not)
• IP address of the CNC C70 specified for the Ping command