(1)When the GOT is
Connect the GOT to the last redundant extension base unit (A68RB) of the Q4ARCPU redundant system.
For the redundant extension base units, use version B or later.
The version can be confirmed in the DATE field of the rating plate.
Caution
Version of redundant extension base unit
Enlarged view of rating plate
POINT
(1)When the GOT is bus connected to the bus switching module (A6RAF) on a redundant main base unit (A32RB/A33RB)
(2)When the GOT is bus connected to a
(2)
Apply the power to the GOT and Q4ARCPU redundant system in the following sequence.
GT Designer3 Version Screen Design
Manual
Set [CPU No.] to "2" in the device setting to monitor the device of the Motion CPU area (CPU No.2).
When the CPU No. is set to "0" or "1", the device on the PLC CPU area (CPU No.1) is monitored.
When the CPU No. is set to the number other than "0" to "2", a communication error occurs and the monitoring cannot be executed.
For setting the CPU No., refer to the following manual.
GT Designer3 Version Screen Design Manual
Example) Setting dialog box of the bit device
5.4.16TroubleshootingFor the troubleshooting, refer to the User's Manual for the GOT you are using.
1
PREPARATORYFORPROCEDURESMONITORING 2
RANGESETBE
DEVICE CANTHAT 3
RANGEACCESS MONITORINGFOR 4
MONITORTOREDUNTANTSYSTEM HOW 5
CONNECTIONBUS 6
DIRECTTOCONNECTIONCPU 7
LINKCOMPUTER CONNECTION 8
ETHERNETCONNECTION
5. BUS CONNECTION | 5 - 39 |
5.4 Precautions |
|