Connecting the GOT and PLC in computer link connection(when connected to the QJ71C24(N)) (GX Configurator is not supported.)
1.
2.
3.
Click [Online] [Transfer Setup] in GX Developer.
The [Transfer Setup] is displayed.
Set the [Transfer Setup]:
PC side I/F | : Serial |
PLC side I/F | : C24 |
Other station | : No specification |
6.
7.
When connecting the GOT and PC with serial When connecting the GOT to PC via modem
Mark the
When connecting the GOT and PC with USB
Mark the [USB] checkbox.
8. The screen returns to [Transfer Setup]. Click [Connection Test] to check if GX Developer has been connected to the QCPU (Q mode).
4.
5.
Return to [Transfer Setup] and
Check [via GOT transparent mode] for [PLC side I/F detailed setting of C24].
22 - 40 | 22. FA TRANSPARENT FUNCTION |
| 22.6 Personal Computer Side Setting |