12.The screen returns to [Transfer Setup]. Click [Connection Test] to check if GX Developer has been connected to the QCPU (Q mode).

Connecting the GOT and PLC in direct CPU connection (when connecting to FXCPU)

1. Click [Online] [Transfer Setup] in GX Developer.

2. The [Transfer Setup] is displayed.

3. Set the [Transfer Setup]:

PC side I/F

: Serial

PLC side I/F

: PLC module

Other station

: No specification

4. Double-click [Serial] of the PC side I/F to display [PC side I/F Serial setting].

5. Check-mark either of the following in [PC side I/F Serial setting].

When connecting the GOT and PC with serial When connecting the GOT to PC via modem

Mark the [RS-232C] checkbox.

When connecting the GOT and PC with USB

Mark the [USB] checkbox.

6. The screen returns to the [Transfer Setup]. Click the [Connection Test] to check if GX Developer has been connected to the FXCPU.

POINT

How to operate GX Developer

For the GX Developer operation method, refer to the following manual.

GX Developer Version Operating Manual

22 - 42

22. FA TRANSPARENT FUNCTION

 

22.6 Personal Computer Side Setting