Setting item

The following describes the setting items for the standard I/F setting and extension I/F setting.

Item

 

 

 

Description

 

 

 

Set channel No. and drivers to the GOT standard interfaces.

Standard I/F setting

 

GT16, GT14, GT12: Standard I/F-1, Standard I/F-2, Standard I/F-3, Standard I/F-4

 

GT15, GT1030, GT1020: Standard I/F-1, Standard I/F-2

 

 

 

 

 

 

GT11, GT105 , GT104 : Standard I/F-1, Standard I/F-2, Standard I/F-3

 

 

 

 

 

 

 

Set the CH No. according to the intended purpose.

 

 

 

The number of channels differs depending on the GOT to be used.

 

 

 

0: Not used

 

 

 

 

 

1 to 4: Used for connecting a controller of channel No. 1 to 4 set in Setting connected equipment (Channel

 

 

 

setting)

 

 

 

CH No.

 

8: Used for fingerprint authentication, barcode function, RFID function, remote personal computer operation

 

 

(serial), report function (when using the serial printer), hard copy function (when using the serial printer) or GOT

 

 

 

 

 

 

(extended computer)

 

 

 

 

9: Used for connecting Host (PC) or Host (modem)

 

 

 

*: Used for remote personal computer operation (Ethernet), Ethernet download, gateway function or MES

 

 

 

interface function

 

 

 

 

Multi: Used for Ethernet multiple connection

 

 

 

 

 

I/F

The communication type of the GOT standard interface is displayed.

 

 

 

 

 

Driver

 

Set the driver for the device to be connected.

 

 

None

Host (Personal computer)

Each communication driver for connected devices

 

 

 

 

 

 

 

 

Detail Setting

 

Make settings for the transmission speed and data length of the communication driver.

 

 

Refer to each chapter of the equipment to be connected to the GOT.

 

 

 

 

 

 

 

 

 

 

 

 

To validate the 5V power supply function in RS232, mark the [Enable the 5V power supply] checkbox.

 

 

 

The RS232 setting is invalid in the following cases.

 

RS232 Setting

 

• CH No. of [I/F-1: RS232] is [9] in GT15 and 16.

 

 

 

• CH No. of [I/F-1: RS232] is [9] or [8] in GT14.

 

 

 

• For GT12, GT11 and GT10

 

 

 

 

 

 

 

 

 

 

 

 

(Continued to next page)

1

PREPARATORYFORPROCEDURESMONITORING 2

RANGESETBE

DEVICE CANTHAT 3

RANGEACCESS MONITORINGFOR 4

MONITORTOREDUNTANTSYSTEM HOW 5

CONNECTIONBUS 6

DIRECTTOCONNECTIONCPU 7

LINKCOMPUTER CONNECTION 8

ETHERNETCONNECTION

1. PREPARATORY PROCEDURES FOR MONITORING

1 - 13

1.1 Setting the Communication Interface