9.4 PLC Side Settings
This section describes the settings of the GOT and MELSECNET/H network module in the case of system configuration shown as 9.4.1.
When connecting the MELSECNET/H network module to the MELSECNET/H network system, specify the MELSECNET/H Mode or the MELSECNET/H Extended Mode as a network type.
POINT
MELSECNET/H network module
For details of the MELSECNET/H network module, refer to the following manual.
Q corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network)
9.4.1System configuration 9.4.4 [Controller Setting] of GT Designer3
<GOT>
9
9.4.2 |
|
|
|
|
| Switch setting of |
|
|
|
|
|
|
|
|
| MELSECNET/H CONNECTION(PLC PLCTONETWORK) | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| MELSECNET/H network |
|
| ||||||||||
|
|
|
|
|
|
| module |
|
|
|
|
|
|
|
|
|
| 10 | |
Set the station number setting switch and mode setting | |||||||||||||||||||
MELSECNET/10 CONNECTION(PLC NETWORK)PLCTO | |||||||||||||||||||
ERR. | L ERR. |
|
| ERR. | L ERR. |
| |||||||||||||
switch. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
QJ71LP21, |
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
| RUN | MNG |
|
|
| ||||||||||
RUN | MNG |
|
|
|
|
|
|
| |||||||||||
T.PASS | D.LINK |
| EXT.PW | T.PASS | D.LINK |
|
| ||||||||||||
SD | RD |
|
|
|
|
|
| SD | RD |
|
|
|
|
| 11 | ||||
X10 | 091 |
|
| 65 |
|
| X10 | 091 |
| 3 |
| 65 |
| ||||||
STATION NO. |
| 2 | 3 | 4 |
|
| STATION NO. |
| 2 | 4 |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
| 8 | 7 |
|
| (1) |
|
|
| 8 | 7 |
|
| (1) | |||||
| 1 | 2 | 34 |
|
| 1 | 2 | 34 | |||||||||||
|
|
|
| 5 |
|
|
|
|
|
|
| 5 |
| ||||||
X1 | 0 |
|
|
|
|
| X1 | 0 |
|
|
|
|
|
| |||||
9 | 7 | 6 |
|
|
| 9 |
| 7 | 6 |
|
|
| |||||||
|
| 8 |
|
|
|
|
|
| 8 |
|
|
|
| ||||||
IN |
|
|
|
|
|
|
|
| IN |
|
|
|
|
|
|
|
|
| |
| 2 | 34 | 5 |
|
| (2) | +24V |
| 2 | 3 | 456 |
| (2) | 12 | |||||
|
|
| 67 | EXT..PW |
|
|
|
|
| 7 |
| ||||||||
MODE | 01 |
|
|
| 8 | MODE | 01 |
|
|
|
| 8 |
| ||||||
E |
|
| A | 9 |
| E |
|
|
| A | 9 |
| |||||||
F | DCB |
|
|
|
| F | DCB |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
(Use the default value for settings other than the following.)
|
|
|
| Network type | : MNET/H Mode | ||
|
|
|
| Network No. | : 1 |
| |
|
|
|
| Station No. | : 2 |
| |
|
|
|
| Made Setting | : Online (auto,reconnection) | ||
|
|
|
|
| 2 | : LB0100H to LB01FFH | |
|
|
|
| Network range assignment * | |||
MELSECNET/H (PLC to PLC network) |
| LW0100H to LW01FFH | |||||
: 10Mbps | |||||||
|
|
|
| Transmission speed |
<MELSECNET/H network module> *1
(Use the default value for settings other than the following.)
Station No. | : 1 |
Mode | : Online (10Mbps) |
Network type | : MNET/H mode (Control station) |
Network No. | : 1 |
Total stations | : 2 |
Network range assignment *2: LB0000H to LB00FFH
LW0000H to LW00FFH
9.4.2Switch setting of MELSECNET/H network module
(1) [Network parameter] of GX Developer
*1 The MELSECNET/H network module is mounted at slot 0 of the base unit.
The start I/O No. of the MELSECNET/H network module is set at "0".
*2 The network type must be set according to the number of assignment of send points for each station.
When the number of assignment is 2000 bytes or less: MELSECNET/H mode
When the number of assignment is 2000 bytes or more: MELSECNET/H Extended Mode
POINT
When connecting to Q170MCPU
When connected to Q170MCPU, the start I/O No. of the MELSECNET/H network module is set to "70".
OUT
QJ71LP21
QJ71BR11
QJ71BR11
RUN | MNG |
|
|
| |||
T.PASS | D.LINK | ||||||
SD | RD |
|
|
|
|
| |
ERR. | L ERR. | ||||||
STATION NO. |
| 2 | 34 |
| |||
X10 | 1 |
| |||||
|
|
| 5 |
| |||
0 |
|
|
|
| |||
| 9 | 8 | 7 | 6 |
|
| |
|
|
|
|
| |||
X1 | 1 | 2 | 34 |
| |||
0 |
|
|
| 5 |
| ||
| 9 | 8 | 7 | 6 |
|
| |
|
|
|
|
| |||
| 2 | 3 | 4 | 56 |
|
| |
|
|
|
| 7 |
| ||
MODE | 01 |
|
|
| 8 |
| |
F |
|
|
| A | 9 |
| |
| E |
|
|
|
| ||
|
| DCB |
|
|
|
QJ71BR11
24G
OUT
(FG)24G
QJ71LP21
(1)
(2)
13
14
15
CONNECTION
INVERTER
16
CONNECTION
SERVO AMPLIFIER
9. MELSECNET/H CONNECTION (PLC TO PLC NETWORK) | 9 - 11 |
9.4 PLC Side Settings |
|