Monitor accessible range of other stations and setting method of monitor devices
Example 1: When using bus connection
| Control station |
| Control station |
| |
| AnU |
| QnA |
| |
|
|
| |||
QnA |
| AnU |
| AnU | |
Network No.1 | Network No.2 | ||||
|
| ||||
|
|
|
| ||
| AnA |
| AnN |
| |
|
|
|
•Monitor accessible range of devices (other than B or W) of other stations or other networks Specify the accessing network No. or station as shown in the following table.
(1)To monitor B or W of the connected station (host station) assigned with a network parameter, specify the host station.
(2)To monitor another station (other than B or W) or another network, specify the station (network No. and station No.).
Station to be accessed |
| Network No.1 |
|
|
| Network No.2 |
| ||||
Station |
| AnU | QnA | AnA | AnU | QnA | AnU | AnN | AnU | ||
connected to GOT | |||||||||||
|
|
|
|
|
|
|
|
| |||
AnU |
|
|
|
|
|
|
|
|
| ||
Host | ── | Other | Other | ── | Other | ── | Other | ||||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
QnA |
|
|
|
|
|
|
|
|
| ||
Other | Host | ── | Other | Other | Other | ── | Other | ||||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
AnA |
|
|
|
|
|
|
|
|
| ||
Other | ── | Host | ── | ── |
| ── | ── | ── | |||
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
| |
AnU |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
Other | ── | ── | Host | ── |
| Host | ── | Other | |||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
QnA |
|
|
|
|
|
|
|
|
| ||
Other | Other | ── | Other | Host | Other | Other | Other | ||||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
AnN |
|
|
|
|
|
|
|
|
| ||
── | ── | ── | ── | ── |
| ── | Host | ── | |||
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
| |
AnU |
|
|
|
|
|
|
|
|
| ||
Other | ── | ── | Other | ── | Other | ── | Host | ||||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| How to read the table |
|
| |||
|
|
|
|
|
| Upper line: | Accessibility |
| |||
|
|
|
|
|
|
|
| : Accessible |
| ||
|
|
|
|
|
|
|
| : Not accessible |
| ||
|
|
|
|
|
| Lower line: | Network settings |
| |||
|
|
|
|
|
|
|
| Host |
|
| |
|
|
|
|
|
|
|
| Other (Network No. - Station number) |
POINT
Monitoring link device B or W
For monitoring devices B and W that are allocated by the link parameter, use the host device number even when designating devices allocated to another station.
Otherwise, the display speed will be reduced.
1
PREPARATORYFORPROCEDURESMONITORING 2
RANGESETBE
DEVICE CANTHAT 3
RANGEACCESS MONITORINGFOR 4
MONITORTOREDUNTANTSYSTEM HOW 5
CONNECTIONBUS 6
DIRECTTOCONNECTIONCPU 7
LINKCOMPUTER CONNECTION 8
ETHERNETCONNECTION
3. ACCESS RANGE FOR MONITORING | 3 - 7 |
3.1 Access Range for Monitoring Stations on Network Systems