8.2.5Connecting to PERIPHERAL I/F (Built-in Ethernet port Motion Controller CPU)

 

 

 

Communication driver

PLC

Q172DCPU-S1

 

 

Q173DCPU-S1

GOT

Ethernet(MELSEC),Q17nNC,CRnD-700

CPU

Q172DSCPU

 

 

 

Q173DSCPU

Connection cable

 

 

 

 

 

Q170MCPU

 

 

 

MR-MQ100

 

 

PLC

 

 

Maximum

GOT

 

Number of

 

 

 

 

 

 

Communi

 

 

 

Model name*3

Connection cable*1

segment

Option device

Model

connectable

cation

 

length*4

equipment

 

type

 

 

 

 

 

 

 

 

 

 

 

 

Motion controller CPU

 

Twisted pair cable

 

 

*2

 

(Q Series)

 

10BASE-T

 

- (Built into GOT)

*5

 

Q172DCPU-S1

 

Shielded twisted pair cable (STP) or

 

 

 

 

 

 

Q173DCPU-S1

Ethernet

unshielded twisted pair cable (UTP):

30m

 

 

16 GOTs for 1 network

Q172DSCPU

Category 3, 4, and 5

 

 

 

 

 

 

 

Q173DSCPU

 

100BASE-TX

 

 

 

 

Q170MCPU

 

Shielded twisted pair cable (STP):

 

GT15-J71E71-100

 

 

MR-MQ100

 

Category 5 and 5e

 

 

 

 

 

 

 

 

 

 

 

*1 The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.

Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network system.

Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.

*2 When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching hub and operate in a 10Mbps/100Mbps mixed environment.

For how to check the function version, refer to the following.

GT16 User's Manual (Hardware)

*3 When using the PERIPHERAL I/F, set as shown below.

Use the GT Designer3 Version1.12N or later.

Select [QnUDE(H)] for [Controller Type] in [Ethernet] of GT Designer3. For [Ethernet] of GT Designer3, refer to the following.

8.3.3 Ethernet setting

*4 A length between a hub and a node.

The maximum distance differs depending on the Ethernet device to be used.

The following shows the number of the connectable nodes when a repeater hub is used.

10BASE-T: Max. 4 nodes for a cascade connection (500m)

100BASE-TX: Max. 2 nodes for a cascade connection (205m)

When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of cascades.

For the limit, contact the switching hub manufacturer.

*5 GT14 models compatible with Ethernet connection are only GT1455-QTBDE and GT1450-QLBDE.

HINT

Direct connection between PERIPHERAL I/F and GOT

The PERIPHERAL I/F and GOT can be directly connected by using a cross cable for the Ethernet connection cable.

8 - 14

8. ETHERNET CONNECTION

 

8.2 System Configuration