15.6 Device Range that Can Be Set

The device ranges of controller that can be used for GOT are as follows.

Note that the device ranges in the following tables are the maximum values that can be set in GT Designer3.

The device specifications of controllers may differ depending on the models, even though belonging to the same series.

Please make the setting according to the specifications of the controller actually used.

When a non-existent device or a device number outside the range is set, other objects with correct device settings may not be monitored.

Setting item

Item

 

 

 

Description

 

 

 

Set the device name, device number, and bit number.

 

The bit number can be set only by specifying the bit of word

 

device.

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitors the inverter of the specified station No.

Device

 

 

0 to 31: To monitor the inverter of the specified

 

Station

station No.

 

 

 

No.

100 to 115: To specify the station No. of the inverter

 

 

 

to be monitored by the value of GOT data register

 

 

 

(GD).*1

 

 

Information

Displays

the device type and setting range which are

selected in [Device].

 

 

 

 

 

 

 

 

*1

 

The following shows the relation between the inverter station

 

 

numbers and the GOT data register.

 

 

 

 

 

 

 

 

 

 

 

Station

GOT data register (GD)

Setting range

 

 

 

No.

 

 

 

 

 

 

 

 

 

 

100

 

GD10

0 to 31

 

 

 

 

 

(If setting a value

 

 

101

 

GD11

 

 

 

 

 

outside the

 

:

 

:

 

 

range above, a

 

 

 

 

 

 

114

 

GD24

 

 

device range

 

 

 

 

 

 

115

 

GD25

error occurs)

 

 

 

 

 

 

 

(1)Setting the device by inputting directly from the keyboard

When setting the device by inputting directly from the keyboard, set the items as follows.

Station No.

Device number

Device name

Inverter (FREQROL 500/700 series)

 

 

 

 

 

Device

 

Device name

 

Setting range

 

No.

 

 

 

represen

 

 

 

 

 

 

 

 

 

 

tation

 

Inverter

RS0: 0

to

RS15: 31

 

device

status monitor

 

RS0: 100

to

RS15: 115

 

(RS)*3

 

 

 

 

Decimal

Run command

 

 

 

 

Bit

WS0: 0

to

RS15: 31

 

(WS)

 

 

WS0: 100

to

RS15: 115

 

 

*4*5

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm definition

A0: 0

to

A7: 31

 

 

(A)

 

 

A0: 100

to

A7: 115

 

 

*2*3

 

 

 

 

 

 

 

 

 

 

 

 

device

Parameter (Pr)

Pr0: 0

to

Pr999: 31

 

*1*2

Pr0: 100

to

Pr999: 115

 

 

 

 

 

 

Programmed

PG0: 0

to

PG89: 31

Decimal

Word

operation

 

PG0: 100

to

PG89: 115

 

(PG)*1*2

 

 

 

 

 

 

Special

SP108: 0

to

SP127: 31

 

 

parameter

 

 

SP108: 100

to

SP127: 115

 

 

(SP)*2*4

 

 

 

 

 

 

*1 When creating the screen, designate only either of programmed operation (PG) device or parameter (Pr) device.

Do no designate both PG (PG0 to PG89) and Pr (Pr900 to Pr905) devices.

*2 Only 16-bit (1-word) designation is possible.

*3 Only reading is possible.

*4 Precautions for PU operation mode

When the GOT is connected to the PU connector and the operation mode is set to the PU operation mode, the multi- speed operation (W3 to W7, SP121, SP122) cannot be used. For using the multi-speed operation, follow either of the operations as below.

Connect the GOT to the RS-485 terminal and set the operation mode to the NET operation mode (Computer link operation mode), and then operate the inverter.

Change the motor speed with the set frequency (SP109, SP110), and then operate the inverter with the forward or

reverse rotation (WS1, WS2, SP121, SP122).

*5 Precautions for WS devices

Only writing is possible for WS devices. More than one WS cannot turn on at once.

(Except the turned on WS device, the other WS devices turn off.)

Bits of SP122 (word device) and SP121 (word device) are assigned to WS0 to WS7 and WS8 to WS15 respectively. When more than one WS turns on at once, convert the values for the bit devices that are assigned to the word device into values for the word device. Write the converted values into SP122 or SP121.

Setting High speed operation command (WS5), Middle speed operation command (WS4), and Low speed operation command (WS3)

When setting High speed operation command (WS5), Middle speed operation command (WS4), and Low speed operation command (WS3), write numerical values to device SP122 as necessary.

As the following figure shows, each operation mode is assigned to device SP122.

The following shows an example for Forward rotation command (WS1) and Low speed operation command (WS3).

15 - 44

15. INVERTER CONNECTION

15.6 Device Range that Can Be Set