(2)CC-Link Utility's [Parameter Settings]

(a)Parameter settings

 

 

 

 

 

Setting

 

Item*1

 

 

Set value

necessity at

 

 

 

GOT

 

 

 

 

 

 

 

 

 

 

connection

Number of modules

 

 

1

 

 

 

 

 

 

Target module

 

 

1

 

 

 

 

 

 

Start I/O No.

 

 

0000H

 

 

 

 

 

 

Channel No.

 

 

(Use default value)

 

 

 

 

 

 

 

 

Type

 

 

Master station

 

 

 

 

 

 

 

 

Mode

 

 

Remote net

 

 

 

 

(Ver.2 mode)

 

settings

 

 

 

 

 

 

 

 

 

Expanded cyclic setting

 

Single

 

 

 

 

 

 

 

 

 

 

Operation

Occupied number

 

 

Exclusive station 1

 

 

 

 

 

 

status

 

 

 

 

 

Error event: input data

 

 

Clear

 

 

 

 

 

 

 

 

 

 

 

 

CPU stop: data link status

 

Refresh

 

 

 

 

 

 

 

 

Other settings

 

 

(Use default value)

 

 

 

 

 

 

 

 

All connect count

 

 

1

 

 

 

 

 

 

 

Station Type

Sta.

Ver.2 intelligent device

 

 

No.1

 

station

 

 

 

 

 

settings

 

 

 

 

 

Expanded cyclic

Sta.

 

Single

 

 

 

 

 

setting*2

No.1

 

 

 

 

 

 

information

 

Sta.

 

 

 

 

Occupied number*2

Sta.

 

Exclusive station 1

 

 

 

No.1

 

 

 

Station

Remote station points

No.1

 

32 points

 

 

 

 

 

 

Reserve/invalid

Sta.

 

No setting

 

 

 

 

 

station select

No.1

 

 

 

 

 

 

 

 

 

 

 

 

 

Intelligent buffer select

 

 

(Use default value)

 

 

(word)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Necessary

: As necessary : Not necessary

*1 When the [Mode] of the CC-Link module is set at [Remote net - (Ver. 2 mode)], [Remote station points] can be set. [Remote station points] is a setting for the remote I/O station. The default value (32 points) must be used on the GOT.

*2 Set the same setting as that of the GOT.

POINT

When changing the network parameter

After writing the network parameter to the C Controller module, either turn the C Controller module OFF and then ON or reset it.

[Communication settings] of GT Designer3

Item

Set value

Station No.

1: Station No.1

 

 

Transmission Rate

0: Online 156kbps

 

 

Mode

Ver.2: Remote net (Ver.2 mode)

 

 

Expanded Cyclic

Single

 

 

Number of stations occupied

1 Station

 

 

Input for Error Station

Clear

 

 

Retry

3times (Use default value)

 

 

Timeout Time

3sec (Use default value)

 

 

Delay Time

0ms (Use default value)

 

 

POINT

[Controller Setting] of GT Designer3

For the setting method of [Controller Setting] of GT Designer3, refer to the following.

13.3.1 Setting communication interface (Communication settings)

9

TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)

10

MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)

11

CC-Link IE CONTROLLER NETWORK CONNECTION

12

CC-Link IE FIELD NETWORK CONNECTION

13

CC-Link CONNECTION (INTELLIGENT DEVICE STATION)

14

CC-Link CONNECTION (Via G4)

15

CONNECTION

INVERTER

16

CONNECTION

SERVO AMPLIFIER

13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)

13 - 19

13.4 PLC Side Setting