10.2.2Connecting to the coaxial bus system

Communication driver

Communication driver

MELSECNET/H

MELSECNET/10

(When MELSECNET/H

(When MELSECNET/10

communication unit is used)

communication unit is used)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MELSECNET/H,

 

 

 

 

 

 

 

PLC

 

 

MELSECNET/10

 

 

 

GOT

 

 

 

 

 

 

network module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLC

 

Connection cable

GOT

 

 

 

 

 

 

 

 

 

Number of

 

MELSECNET/H,

 

 

 

 

 

 

 

 

 

 

 

connectable

Model name

MELSECNET/10

Communication

Cable model

Max.

Option device

Model

equipment

network module

type

distance

 

 

 

 

 

 

 

 

 

 

*2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MELSEC-Q

QJ71BR11*1

MELSECNET/10

Coaxial cable

*4

GT15-J71BR13*5

 

 

 

 

 

*1

*3

GT15-75J71BR13-Z*6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C Controller

 

 

Coaxial cable

 

 

 

 

module

QJ71BR11*1

MELSECNET/10

*4

GT15-J71BR13*5

 

 

*3

 

 

MELSEC-QS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31 GOTs

MELSEC-QnA

AJ71QBR11

MELSECNET/10

Coaxial cable

*4

GT15-J71BR13*5

 

 

 

 

 

 

A1SJ71QBR11

*3

GT15-75J71BR13-Z*6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MELSEC-A

AJ71BR11

MELSECNET/10

Coaxial cable

*4

GT15-J71BR13*5

 

 

 

 

 

A1SJ71BR11

*3

GT15-75J71BR13-Z*6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 Use a PLC CPU and MELSECNET/H network module of function version B or later.

*2 For the system configuration of the MELSECNET/H and MELSECNET/10 network module, refer to the following manuals.

Q corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network) For QnA/Q4AR MELSECNET/10 Network System Reference Manual

Type MELSECNET/10 Network system (PLC to PLC network) Reference Manual *3 For the coaxial cable, refer to the following manuals.

Q corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network) For QnA/Q4AR MELSECNET/10 Network System Reference Manual

Type MELSECNET/10 Network system (PLC to PLC network) Reference Manual

*4 The overall extension cable length and the length between stations vary depending on the cable type to be used and the total number of stations.

For details, refer to the following manual.

Q corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network) For QnA/Q4AR MELSECNET/10 Network System Reference Manual

Type MELSECNET/10 Network system (PLC to PLC network) Reference Manual

*5 Specify the MELSECNET/10 Mode as the Communication Settings.For the setting, refer to the following.

10.3.1 Setting communication interface (Communication settings) *6 Not available for the GT155 .

10 - 8

10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)

 

10.2 System Configuration