18.2.4Ethernet connection

MELDAS

Expansion

GOT

Communication driver

C6/C64

unit

 

 

 

 

Connection cable

 

 

 

 

Ethernet(MELSEC),Q17nNC,CRnD-700

 

CNC

 

Connection cable*1

 

GOT

 

Number of

 

 

Commun

 

Maximum

 

 

 

 

 

 

 

connectable

Model name

Expansion unit

ication

Cable model

segment

Option device

Model

equipment

 

 

type

 

length*3

 

 

 

 

 

 

Twisted pair cable

 

 

*2

 

 

 

 

10BASE-T

 

- (Built into GOT)

 

 

 

 

 

Shielded twisted pair cable

 

 

 

 

 

 

 

(STP) or unshielded twisted

 

 

 

128 GOTs

 

 

 

 

 

 

 

FUC6-EX875

 

pair cable (UTP): Category

 

 

 

MELDAS C6/C64

Ethernet

100m

 

 

(recommended to

*4*5

3, 4, and 5

 

 

 

 

 

 

 

16 units or less)

 

 

 

100BASE-TX

 

GT15-J71E71-100

 

 

 

 

 

 

 

 

 

 

Shielded twisted pair cable

 

 

 

 

(STP):

Category 5 and 5e

*1 The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.

Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network system.

Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards. A cross cable is available for connecting the GOT to the Ethernet module.

*2 When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching hub and operate in a 10Mbps/100Mbps mixed environment.

For how to check the function version, refer to the following. GT16 User's Manual

*3 A length between a hub and a node.

The maximum distance differs depending on the Ethernet device to be used.

The following shows the number of the connectable nodes when a repeater hub is used.

10BASE-T: Max. 4 nodes for a cascade connection (500m)

100BASE-TX: Max. 2 nodes for a cascade connection (205m)

When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of cascades.

For the limit, contact the switching hub manufacturer.

*4 For the system configuration of the expansion unit, refer to the following manuals.

C6/C64/C64T CONNECTION AND MAINTENANCE MANUAL BNP-B2255

C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373 *5 Select [AJ71QE71] for [Controller Type] in [Ethernet] of GT Designer3.

For [Ethernet] of GT Designer3, refer to the following. 18.4.3 Ethernet setting

18 - 6

18. CNC CONNECTION

 

18.2 System Configuration