2.1 MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700

The table below shows the device ranges in [MELSEC-

QnU/DC, Q17nD/M/NC/DR, CRnD-700]*10as the controller type.

 

Device name*7

 

Setting range

Device No.

 

 

representation

 

 

 

 

 

 

 

Input (X)

 

X0

to

X3FFF

Hexadecimal

 

Output (Y)

 

Y0

to

Y3FFF

 

 

 

 

Internal relay (M)*4*6*11

M0

to

M61439

 

 

 

 

 

 

Decimal

 

Latch relay (L)

L0

to

L32767

 

Annunciator (F)

F0

to

F32767

 

 

Link relay (B)*4

B0

to

B9FFFF

Hexadecimal

 

Timer*6

Contact (TT)

TT0

to

TT32767

 

 

Coil (TC)

TC0

to

TC32767

 

 

 

 

device

Counter*6

Contact (CT)

CT0

to

CT32767

 

Coil (CC)

CC0

to

CC32767

Decimal

 

Special relay

(SM)

SM0

to

SM2255

Bit

 

 

 

 

 

 

Retentive

Contact (SS)

SS0

to

SS32767

 

 

timer*6

Coil (SC)

SC0

to

SC32767

 

 

Step relay (S)

S0

to

S32767

 

 

Link special relay (SB)

SB0

to

SB7FFF

Hexadecimal

 

 

 

Specified bit of the

 

 

 

 

following word devices

 

 

Word device bit

(Except Timer, Counter,

 

Retentive timer, Index

 

 

 

 

 

 

 

register and Buffer

 

 

 

 

 

memory)

 

 

 

 

 

 

 

 

Word device

Device name*7

 

Setting range

Device No.

 

representation

 

 

 

 

 

Data register (D)*4*6*11

D0

to

D4910079

Decimal

Special data register (SD)

SD0

to

SD2255

 

Link register (W)*4

W0

to

W4AEBFF

Hexadecimal

Timer (current value) (TN)*6

TN0

to

TN32767

 

Counter (current value)

CN0

to

CN32767

 

(CN)*6

 

Decimal

 

 

 

 

Retentive timer

SN0

to

SN32767

 

(current value) (SN)*6

 

 

 

 

 

Link special register (SW)

SW0

to

SW7FFF

Hexadecimal

File register (R)*1*2

R0

to

R32767

 

Extension

Block

0

to

255

 

file register

Device

ER0

to

ER32767

 

(ER)*1

 

 

 

 

 

 

Extension file register

ZR0

to

ZR4849663

 

(ZR)*1*3*4

 

 

 

 

 

 

 

 

 

 

 

Decimal

Index register (Z)

Z0

to

Z19

Buffer memory

 

 

 

 

(Intelligent function module)

BM0

to

BM32767

 

(BM)*5

 

 

 

 

 

Buffer memory

 

 

 

 

(Intelligent function module)

G0

to

G65535

 

(G)*4*5

 

 

 

 

 

Ww*8*9

 

Ww0

to

Ww1FFF

 

Wr*8*9

 

Wr0

to

Wr1FFF

 

Multiple CPU high speed

U3E010000 to U3E024335

 

transmission memory (U3E0)

 

 

 

 

 

 

 

 

 

 

Multiple CPU high speed

U3E110000 to U3E124335

Hexadecimal

transmission memory (U3E1)

 

 

 

 

 

 

 

 

 

Multiple CPU high speed

U3E210000 to U3E224335

 

transmission memory (U3E2)

 

 

 

 

 

 

 

 

 

 

Multiple CPU high speed

U3E310000 to U3E324335

 

transmission memory (U3E3)

 

 

 

 

 

 

 

 

 

 

Motion device (#)

#0

to

#12287

Decimal

 

 

Converting the above bit

 

Bit device word*8*12

devices into words

(Except Timer, Counter

 

 

 

 

 

and Retentive timer)

 

 

 

 

 

 

 

*1 Do not set a file register by GT Designer3 when executing multiple programs with the file of the file register set at [Use the same file name as the program] by the PLC parameter of GX Developer.

Otherwise, read/write at GOT will be erroneous.

*2 Available for file register of block No. switched with the RSET instruction.

*3 Available for file register of block No. of file name switched with the QDRSET instruction.

*4 GOT treats them in units of 32k (32768 points).

*5 Only the intelligent function module on the station connected to GOT can be specified.

Set within the address range of the buffer memory existing in the target intelligent function module.

*6 Do not use local devices set in the MELSEC-Q system. Otherwise, normal monitoring is not performed.

*7 Even though Universal model QCPU processes 64-bit data, the GOT cannot monitor 64-bit data.

*8 This is not supported by GT10.

*9 This cannot be monitored when in GOT multi-drop connection.

*10 For GT14, GT11 and GT10, the controller type is as follows.

GT14, GT11: MELSEC-QnU/DC, Q17nD/M/NC/DR

GT10: MELSEC-QnU/DC

*11 For monitoring the internal relay (M) or data register (D) of a C Controller module, configure the settings related to the device functions in the device setting tab of the language controller setting utility.

*12 The device No. must be set in multiples of 16.

2 - 8

2. DEVICE RANGE THAT CAN BE SET

 

2.1 MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700