Setting

 

Item*1

 

 

 

Set value

necessity at

 

 

 

 

GOT

 

 

 

 

 

 

 

 

 

 

 

 

connection

settings

 

 

Sta.

 

No setting

 

 

 

 

 

 

 

Reserve/invalid

 

No.1

 

 

 

 

 

 

 

 

 

 

 

 

 

information

station select

 

Sta.

 

No setting

 

 

 

 

 

 

 

No.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Station

Intelligent buffer select

 

(Use default value)

 

(word)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Necessary

: As necessary : Not necessary

*1 When the [Mode] of the CC-Link module is set at [Remote net - (Ver. 2 mode)], [Remote station points] can be set. [Remote station points] is a setting for the remote I/O station. The default value (32 points) must be used on the GOT.

*2 Set the same setting as that of the GOT.

POINT

When changing the network parameter

After writing the network parameter to the C Controller module, either turn the C Controller module OFF and then ON or reset it

[Controller Setting] of GT Designer3

(1)Communication Settings of station No.1 (GOT)

(a)When MODEL GT15-J61BT13 CC-Link communication unit is used

Item

Set value

Station No.

1: Station No.1

 

 

Transmission Rate

0: Online 156kbps

 

 

Mode

Ver.1: Remote net (Ver.1 mode)

 

 

Expanded Cyclic

Single (Use default value)

 

 

Number of stations occupied

1 Station

 

 

Input for Error Station

0: Clear

 

 

Retry

3times (Use default value)

 

 

Timeout Time

3sec (Use default value)

 

 

Delay Time

0ms (Use default value)

 

 

(b)When MODEL GT15-75J61BT13-Z CC-Link communication unit is used

Item

Set value (Use default value)

Retry

3times

 

 

Timeout Time

3sec

 

 

(2) Communication Settings of station No.2 (GOT)

Item

Set value (Use default value)

Station No.

2: Station No.2

 

 

Transmission Rate

0: Online 156kbps

 

 

Mode

Ver.2: Remote net (Ver.2 mode)

 

 

Expanded Cyclic

Single

 

 

Number of stations occupied

1 Station

 

 

Input for Error Station

0: Clear

 

 

Retry

3times (Use default value)

 

 

Timeout Time

3sec (Use default value)

 

 

Delay Time

0ms (Use default value)

 

 

Setting of the CC-Link communication unit (Only when MODEL GT15-75J61BT13-Z CC-Link communication unit is used)

 

Item

Set value

Mode setting switch

0: Online (fixed)

 

 

Station number setting switch

1: Station No.1

 

 

Transmission baudrate setting switch

0: 156kbps

 

 

 

Condition

SW1 (Input data status of the

OFF: Cleared

data link error station)

setting

 

 

 

SW2 (Number of occupied

 

switches

OFF: 1 station

stations)

 

 

 

 

 

POINT

Setting of the CC-Link communication unit

For the setting method of the CC-Link communication unit, refer to the following.

13.3.3 Switch setting (Only when MODEL GT15-75J61BT13-ZCC-Link communication unit is used)

9

TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)

10

MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)

11

CC-Link IE CONTROLLER NETWORK CONNECTION

12

CC-Link IE FIELD NETWORK CONNECTION

13

CC-Link CONNECTION (INTELLIGENT DEVICE STATION)

14

CC-Link CONNECTION (Via G4)

15

CONNECTION

INVERTER

16

CONNECTION

SERVO AMPLIFIER

13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)

13 - 23

13.4 PLC Side Setting