19.2 Connectable Model List

17

Connecting the CPU to the Serial Multi-Drop Connection Unit (hereinafter referred to as "master module") directly

The following table shows the connectable models.

 

 

 

Communication type

 

 

 

 

 

 

 

 

 

Series

Model name

Clock

Between CPU

Between

 

 

 

 

 

 

 

 

 

and master

master module

 

 

 

 

 

 

 

 

 

 

 

 

module

and GOT

 

 

 

 

 

 

 

 

 

 

Q00JCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q00CPU*1

 

 

 

 

 

 

 

 

 

 

 

 

 

Q01CPU*1

 

 

 

 

 

 

 

 

 

 

 

 

 

Q02CPU*1

 

RS-232

 

 

 

 

 

 

 

 

 

 

 

Q02HCPU*1

 

RS-422

 

 

 

 

 

 

 

 

 

 

 

Q06HCPU*1

 

 

 

 

 

 

 

 

 

 

 

 

 

Q12HCPU*1

 

 

 

 

 

 

 

 

 

 

 

 

 

Q25HCPU*1

 

 

 

 

 

 

 

 

 

 

 

 

 

Q02PHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q06PHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q12PHCPU

 

RS-232

 

 

 

 

 

 

 

 

 

 

 

Q25PHCPU

 

RS-422

 

 

 

 

 

 

 

 

 

 

 

Q12PRHCPU (Main base)

 

 

 

 

 

 

 

 

 

 

 

 

 

Q25PRHCPU (Main base)

 

 

 

 

 

 

 

 

 

 

 

 

 

Q12PRHCPU (Extension base)

 

-

 

 

 

 

 

 

 

 

 

 

 

Q25PRHCPU (Extension base)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q00UJCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q00UCPU

 

 

 

 

 

 

 

 

 

 

 

 

MELSEC-Q

Q01UCPU

 

 

 

 

 

 

 

 

 

 

 

 

Q02UCPU

 

 

 

 

 

 

 

 

 

 

 

 

(Q mode)*5

 

 

 

 

 

 

 

 

 

 

 

 

 

Q03UDCPU

 

RS-232

 

 

 

 

 

 

 

 

 

 

 

Q04UDHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-422

 

 

 

 

 

 

 

 

 

 

 

Q06UDHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q10UDHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q13UDHCPU

 

 

RS-485

 

 

 

 

 

 

 

 

 

 

Q20UDHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q26UDHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q03UDECPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q04UDEHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q06UDEHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q10UDEHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q13UDEHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q20UDEHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q26UDEHCPU

 

RS-232

 

 

 

 

 

 

 

*2

*2

*2

 

Q50UDEHCPU

 

 

*2

*2

*2

*2

 

 

 

 

 

 

 

 

 

 

Q100UDEHCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q03UDVCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q04UDVCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q06UDVCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q13UDVCPU

 

 

 

 

 

 

 

 

 

 

 

 

 

Q26UDVCPU

 

 

 

 

 

 

 

 

 

 

 

 

C Controller

Q12DCCPU-V*4

 

RS-232

 

 

 

 

 

 

 

*2

*2

*2

module

Q24DHCCPU-V

 

 

*2

*2

*2

*2

 

 

 

 

 

 

 

 

MELSEC-QS*5

QS001CPU

 

-

 

 

 

 

 

 

 

 

 

 

 

L02CPU*3

 

 

 

 

 

 

 

 

 

 

 

 

 

L26CPU*3

 

 

 

 

 

 

 

 

 

 

 

 

MELSEC-L*5

L26CPU-BT*3

 

RS-232

 

 

 

 

 

 

 

 

 

 

L02CPU-P*3

 

RS-422

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L26CPU-PBT*3

 

 

 

 

 

 

 

 

 

 

 

 

 

L02SCPU

 

 

 

 

 

 

 

 

 

 

 

 

(Continued to next page)

*1 When in multiple CPU system configuration, use CPU function version B or later. *2 Access via the (RS-232) in the multiple CPU system.

*3 When connecting in direct CPU connection, the adapter L6ADP-R2 is required. *4 Use a module with the upper five digits of the serial No. later than 12042.

*5 Ww and Wr devices cannot be monitored.

ROBOT CONTROLLER CONNECTION

18

CNC CONNECTION

19

CONNECTION

GOT MULTI-DROP

20

MULTIPLE-GT14, GT12, GT11, GT10 CONNECTION FUNCTION

21

FUNCTION

MULTI-CHANNEL

22

FUNCTION

FA TRANSPARENT

19. GOT MULTI-DROP CONNECTION

19 - 3

19.2 Connectable Model List