8.2.4Connection to CC-Link IE Field Network Ethernet Adapter Module

Communication driver

Ethernet(MELSEC),

Q17nNC, CRnD-700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CC-Link IE Field

 

 

 

CC-Link IE

 

 

 

 

 

 

 

QCPU

 

Network Master/

 

 

 

Field Network

 

 

 

GOT

 

 

 

 

 

 

 

Ethernet adapter

 

 

 

 

 

 

 

 

 

Local module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection cable 1)

 

module

 

Connection cable 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CC-Link IE

 

 

 

 

 

 

 

 

PLC

Connection cable 1)*4

Field Network

Connection cable 2)*1

GOT

 

 

 

 

 

 

 

Ethernet adapter module

 

 

 

 

 

Number of

 

 

CC-Link IE

 

 

Commu

 

 

Commu

Cable model

Maximu

 

 

 

connectable

 

 

Field Network

Cable

Max.

Model

 

m

Option

 

 

equipment

Model name

nication

 

nication

Connection diagram

 

Model

Master/Local

model

distance

name

 

segment

device

 

 

 

 

type

 

type

number

 

 

 

 

 

module

 

 

 

 

length*3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Twisted pair cable

 

 

 

*2

 

 

 

 

 

 

 

 

 

 

10BASE-T

 

- (Built into

 

*7

 

MELSEC-Q

 

 

 

 

 

 

 

 

Shielded twisted pair

 

 

 

 

 

 

 

 

 

 

 

 

GOT)

 

 

 

(Q mode)

 

 

 

 

 

 

 

 

cable (STP) or

 

 

 

 

 

 

Double-

 

 

 

 

 

 

 

 

 

128 GOTs*6

 

 

 

 

 

 

 

 

unshielded twisted

 

 

 

 

 

 

 

shielded

 

CC-Link

NZ2GF

 

 

 

 

 

 

(recommend

Motion

 

QJ71GF11-T2

100m

 

Ethernet

pair cable (UTP):

100m

 

 

 

 

twisted pair

 

 

 

 

Controller

 

 

 

IE

-ETB

 

 

Category 3, 4, and 5

 

 

 

 

ed to 16 units

 

 

cable*4

 

 

 

 

 

 

 

 

 

or less)

CPU (Q

 

 

 

 

 

 

 

100BASE-TX

 

GT15-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Series)

 

 

 

 

 

 

 

 

Shielded twisted pair

 

J71E71-100

 

 

 

 

 

 

 

 

 

 

 

 

cable (STP):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Category 5 and 5e

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system. Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network system.

Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard. A cross cable is available for connecting the GOT to the Ethernet module.

*2 When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching hub and operate in a 10Mbps/100Mbps mixed environment.

For how to check the function version, refer to the following.

GT16 User's Manual (Hardware) *3 A length between a hub and a node.

The maximum distance differs depending on the Ethernet device to be used.

The following shows the number of the connectable nodes when a repeater hub is used.

10BASE-T: Max. 4 nodes for a cascade connection (500m)

100BASE-TX: Max. 2 nodes for a cascade connection (205m)

When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of cascades.

For the limit, contact the switching hub manufacturer.

*4 Use cables with the following specifications.

Connector

Range

Category 5e or higher

Cable that satisfies the following specifications:

IEEE802.3 1000BASE-T

Shielded RJ-45

ANSI/TIA/EIA-568-B(Category 5e)

 

 

 

*5 For the system configuration on the CC-Link IE Field Network module side, refer to the following manual.

CC-Link IE Field Network Ethernet Adapter Module User's Manual *6 The number of connectable GOTs for one network is 63 units (at most).

*7 GT14 models compatible with Ethernet connection are only GT1455-QTBDE and GT1450-QLBDE.

1

PREPARATORYFORPROCEDURESMONITORING 2

RANGESETBE

DEVICE CANTHAT 3

RANGEACCESS MONITORINGFOR 4

MONITORTOREDUNTANTSYSTEM HOW 5

CONNECTIONBUS 6

DIRECTTOCONNECTIONCPU 7

LINKCOMPUTER CONNECTION 8

ETHERNETCONNECTION

8. ETHERNET CONNECTION

8 - 13

8.2 System Configuration