15.7Precautions
Station No. of inverter system
Make sure to establish inverter system with No.0 station.
Number of inverter
Up to 31 inverters can be connected.
For GT11 and GT10, refer to the following manual for the procedure to check the connectable inverter depending on the version.
GT11 User's Manual, GT10 User's Manual
Model name | Hardware version | Number of connect- | ||
able Inverter | ||||
|
|
| ||
C or later | 31 | |||
|
| |||
B or earlier | 10 | |||
|
| |||
|
|
|
| |
F or later | 31 | |||
|
| |||
E or earlier | 10 | |||
|
| |||
|
|
|
| |
C or later | 31 | |||
|
| |||
B or earlier | 10 | |||
|
| |||
|
|
| ||
A or later | 31 | |||
|
| |||
|
|
|
| |
D | B or later | 31 | ||
|
| |||
D | A or earlier | 10 | ||
|
|
|
| |
D | E or later | 31 | ||
|
| |||
D or earlier | 10 | |||
|
| |||
|
|
|
|
Parameter setting
(1)Communication parameter change
Do not make any change for each communication parameter of the inverter side from GOT.
If changed, the communication to the inverter cannot be made.
(2)When setting "8888" or "9999" to inverter parameter (Pr)
"8888" and "9999" designate special function. When specifying from the GOT, it will be as follows.
Set value of inverter side | Value specified by GOT |
8888 | 65520 |
|
|
9999 | 65535 |
|
|
Screen switching devices, system information devices
Make sure to use GD for screen switching devices and system information devices when the GOT is connected to only the inverter.
GOT clock control
Since the inverter does not have a clock function, the settings of [time adjusting] or [time broad cast] by GOT clock control will be disabled.