POINT
Switch setting of the communication unit
When using the MELSECNET/H communication unit, the switch setting is not needed.
For details of each setting switch and LED, refer to the following manual.
GT15 MELSECNET/10 communication unit User's Manual
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
| RUN | POWER |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| PC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DUAL | D.LINK |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| SW.E | T.PASS |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| M/S.E |
|
|
|
| E |
|
|
|
|
|
|
|
|
|
|
|
| E PRM.E | GOT R/W |
|
|
|
|
|
|
|
| |||||
|
|
|
| R | CRC | CRC |
|
| R |
|
|
|
|
|
|
|
| |
|
|
|
| R | OVER | OVER |
|
| R |
|
|
|
|
|
|
|
| |
|
|
|
| O | AB.IF | AB.IF |
|
| O |
|
|
|
|
|
|
|
| |
|
|
|
| R |
|
| R |
|
|
|
|
|
|
|
| |||
|
|
|
|
| TIME | TIME |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| DATA | DATA |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| UNDER | UNDER |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| LOOP | LOOP |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| SD | SD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RD | RD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| F.LOOP | R.LOOP |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| 4 | 5 | 6 |
|
| (2) |
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | 0 | 9 |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| 3 |
| 7 | GROUP No. |
|
| |
|
|
|
|
|
|
|
|
|
|
|
| 2 |
| 8 |
|
| ||
(4) |
|
|
|
|
|
|
| 7 | 8 | 9A |
| 1 | 5 | 6 |
|
|
|
|
|
|
|
|
|
| 21 | 0FED |
| 0 | 9 8 |
|
|
|
| ||||
|
|
|
|
|
|
| 6 |
|
| B |
| 4 |
| 7 |
|
|
|
|
|
|
|
|
|
| MODE | 45 |
|
| C |
| 3 |
|
| X100 |
|
|
|
|
|
|
|
|
| 3 |
|
|
| 2 |
|
|
|
|
| |||
|
|
|
|
|
|
| 4 | 5 | 6 |
| 4 | 5 | 6 |
| No. | (1) |
| |
|
|
|
|
|
|
| 1 | 0 | 9 8 |
| 1 | 0 | 9 8 |
|
| |||
(3) |
|
|
|
|
|
| 3 |
|
| 7 | X10 | 3 |
| 7 | X10 NETWORK |
|
| |
|
|
|
|
|
| 2 |
|
|
| 2 |
|
|
|
| ||||
|
|
|
|
| No. | 4 | 5 | 6 |
| 4 | 5 | 6 |
|
|
|
| ||
|
|
|
|
| STATION |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 3 |
|
| 7 | X1 | 3 |
| 7 | X1 |
|
|
|
|
|
|
|
|
|
| 2 |
|
| 8 | 2 |
| 8 |
|
|
| ||
|
|
|
|
|
|
| 1 | 0 | 9 |
| 1 | 0 | 9 |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
(1) Network number setting switch |
|
| ||||||||||||||||
Network number setting |
| Description |
| Set value | ||||||||||||||
|
|
|
| switch |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
4 | 5 | 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
|
| 7 | X100 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
2 |
|
| 8 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
1 | 0 | 9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Set the network No. of |
|
| |
| 5 | 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
4 |
|
|
|
|
|
|
|
|
|
|
|
|
| the MELSECNET/10 |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
3 |
|
| 7 | X10 |
| NETWORK |
| 1 to 239 | ||||||||||
|
|
|
|
|
| |||||||||||||
2 |
|
| 8 |
|
| communication unit. |
| |||||||||||
1 | 0 | 9 |
|
|
| No. |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (Default: 001) |
|
| |
| 5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
4 | 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
3 |
|
| 7 | X1 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
2 |
|
| 8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1 | 0 | 9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
(2) Group number setting switch |
|
| ||||||||||||||||
Group number setting |
|
| Description |
| Set value | |||||||||||||
|
|
|
| switch |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 5 | 6 |
|
|
|
|
|
|
|
|
|
|
| Set the group No. of the | 0: | |
| 4 |
|
|
|
|
|
|
|
|
|
|
| MELSECNET/10 |
| ||||
| 3 |
|
|
| 7 |
|
|
|
|
|
|
|
|
|
|
| No group | |
2 |
|
|
| 8 GROUP No. |
|
|
| communication unit. |
| |||||||||
|
| 1 | 0 | 9 |
|
|
|
|
|
|
|
|
|
|
| setting (fixed)*1 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| (Default: 0) |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| *1 The GOT does not use the group number. |
| ||||||||||||||
|
|
|
|
|
| Specify "0". |
|
|
|
|
(3) Station number setting switch
Station number setting | Description | Set value | ||||||
| switch |
|
| |||||
|
|
|
|
| ||||
4 | 5 | 6 |
| Set the station No. of the |
| |||
3 |
|
| 7 | X10 | MELSECNET/10 | 1 to 64: GT15- | ||
|
|
|
|
| ||||
|
|
|
|
| 8 | |||
| 2 |
|
| |||||
| 1 |
|
| 9 |
| communication unit. | ||
STATION | 0 |
| ||||||
|
|
|
|
| ||||
|
|
| 6 |
| Set to not duplicate other | 1 to 32: GT15- | ||
No. | 4 | 5 |
| |||||
|
|
|
|
|
|
| ||
| 2 |
|
| 8 | X1 | stations in the network. | ||
| 3 |
|
| 7 |
|
|
| |
|
|
|
|
|
|
|
| |
1 | 0 | 9 |
| (Default: 01) |
| |||
|
|
|
|
| ||||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
(4) Mode setting switch
Mode setting switch | Description | Set value | ||||||||
| 56 | 7 | 8 | 9 |
|
|
|
| ||
|
|
| B |
| ||||||
|
|
|
|
| A |
|
| 0 | ||
MODE | 4 |
|
|
|
|
|
| C | (Default: 0) | |
|
|
|
|
|
| |||||
3 |
|
|
| E | ||||||
| 2 |
|
| D |
| |||||
|
|
| 1 | 0 | F |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
POINT
(1) Switch setting example
For the switch setting example, refer to the following.
(2) When the switch setting is changed
When changing the switch setting after mounting the MELSECNET/10 communication unit to the GOT, reset the GOT.
(3) Self check test
Select "6" to "9" as the mode setting switch to provide a self check test of the MELSECNET/10 communication unit.
For details, refer to the following manual.
GT15 MELSECNET/10 communication unit User's Manual
9
TO CONNECTIONPLC MELSECNET/H(PLCNETWORK)
10
MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
11
12
13
14
15
CONNECTION
INVERTER
16
CONNECTION
SERVO AMPLIFIER
10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK) | 10 - 11 |
10.3 GOT Side Settings |
|