(3)When connecting the GOT and PLC in computer link connection The following shows the software and the accessible PLC CPUs.

PLC CPU

 

 

Software

 

MELSOFT Navigator*4

 

 

 

GX Developer*1

 

 

QCPU (Q mode)

GX Works2*5

 

 

PX Developer*2

 

 

 

 

 

 

GX Configurator-QP*3

 

 

 

MX Component*9,

MX Sheet*10

 

 

MELSOFT Navigator*8

 

 

LCPU

GX Developer*6

 

 

GX Works2*7

 

 

 

GX LogViewer

 

 

 

MX Component*9,

MX Sheet*10,

LCPU Logging Configuration Tool*11

Motion controller CPU (Q Series)

MX Component*12,

MX Sheet*13

 

*1 GX Developer Version 8.62Q or later is required to use the FA transparent function.

GX Developer Version 8.68W or later is required to use the FA transparent function when connecting the QnUDE(H)CPU to the GOT.

*2 PX Developer Version 1.18U or later is required to use the FA transparent function.

*3 GX Configurator-QP Version2.32J or later is required to use the FA transparent function.

*4 MELSOFT Navigator Version 1.04E or later is required to use the FA transparent function.

*5 GX Works2 Version 1.03D or later is required to use the FA transparent function.

*6 GX Developer Version 8.88S or later is required to use the FA transparent function.

*7 GX Works2 Version 1.11M or later is required to use the FA transparent function.

*8 MELSOFT Navigator Version 1.07H or later is required to use the FA transparent function.

*9 MX Component Version 3.14Q or later is required to use the FA transparent function.

*10 Use MX Component Version 3.14Q or later for MX Sheet.

*11 LCPU Logging Configuration Tool Version 1.04E or later is required to use the FA transparent function.

*12 MX Component Version 4.00A or later is required to use the FA transparent function.

*13 MX Component Version 4.00A or later is required for MX Sheet to use the FA transparent function.

(4)When connecting the GOT and PLC in Ethernet communication The following shows the software and the accessible PLC CPUs.

PLC CPU

 

 

Software

 

MELSOFT Navigator*3

 

 

 

GX Developer*2

 

 

QCPU (Q mode)*1, C Controller module

GX Works2*4*13

 

 

 

MX Component*11,

MX Sheet*12

 

 

Setting/Monitoring tool for C Controller module*18

 

MELSOFT Navigator*10

 

LCPU

GX Developer*7

 

 

GX Works2*8

 

 

 

GX LogViewer

 

 

 

MX Component*11,

MX Sheet*12,

LCPU Logging Configuration Tool*14

FXCPU

GX Works2*19

 

 

QCPU (A mode), QnA/ACPU*1

GX Developer*2

 

 

MX Component*11,

MX Sheet*12

 

 

 

Motion controller CPU (Q Series)

MELSOFT Navigator*3

 

 

MT Works2*5*9

 

 

 

 

 

CNC CPU(Q173NCCPU)

NC Configurator*6

 

 

Robot controller (CRnQ-700, CRnD-700)

RT ToolBox2*15

 

 

MELSERVO(MR-J3-B) *17

MR Configurator2

 

 

MELSERVO(MR-J4-B) *17

MR Configurator2*16

 

 

*1 Only QCPU can be connected.To connect to QnA/ACPU, connect via QCPU.

*2 GX Developer Version 8.78G or later is required to use the FA transparent function.

*3 MELSOFT Navigator Version 1.04E or later is required to use the FA transparent function.

*4 GX Works2 Version 1.10L or later is required to use the FA transparent function.

*5 MT Works2 Version 1.08J or later is required to use the FA transparent function.

*6 NC Configurator Version A1 or later is required to use the FA transparent function.

*7 GX Developer Version 8.88S or later is required to use the FA transparent function.

*8 GX Works2 Version 1.11M or later is required to use the FA transparent function.

*9 MT Works2 Version 1.12N or later is required to connect with Q17nDCPU-S1.

*10 MELSOFT Navigator Version 1.07H or later is required to use the FA transparent function.

*11 MX Component Version 3.14Q or later is required to use the FA transparent function.

*12 Use MX Component Version 3.14Q or later for MX Sheet.

*13 GX Works2 Version 1.34L or later is required to execute the FA transparent function with using CC-Link IE Field Network Ethernet adapter (NZ2GF-ETB).

C controller module does not support CC-Link IE Field Network.

*14 LCPU Logging Configuration Tool Version 1.04E or later is required to use the FA transparent function.

*15 RT ToolBox2 Version 1.7 or later is required to use the FA transparent function.

*16 MR Configurator2 Version 1.09K or later is required to use the FA transparent function.

*17 A motion controller is required between the GOT and PLC in Ethernet connection.

*18 Setting/Monitoring tool for C Controller module Version 4.00A or later is required to use the FA transparent function.

*19 GX Works2 Version 1.98C or later is required to use the FA transparent function.

22 - 8

22. FA TRANSPARENT FUNCTION

 

22.2 Compatible Software